![Falcon DOMINATOR PLUS E3405 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/falcon/dominator-plus-e3405/dominator-plus-e3405_installation-and-servicing-instructions_3264969005.webp)
SECTION 3 - SERVICING and
MAINTENANCE
BEFORE ATTEMPTING ANY MAINTENANCE, ISOLATE APPLIANCE AT MAIN SWITCH AND TAKE STEPS TO
ENSURE THAT IT IS NOT INADVERTENTLY SWITCHED ON.
3.1 CONTROL PANEL REMOVAL
Remove 2 panel fixings from below hob. Release 3 fixings from below control panel.
Pull panel forward slightly from below and allow it to slide down until clear.
This will allow access to mains terminal block, neons and on/off switch
To access gantry element, remove 10 fixings from around gantry. Disconnect element wires then remove securing clip.
Replace in reverse order.
To access lower element, remove control panel and one side panel. Disconnect element cables.
Remove support bracket nuts, lower element tray and remove element. Replace in reverse order.
Supply Cord Replacement
If supply cord is damaged, it must be replaced by the manufacturer, service agent or a suitably qualified person.
Note
: If any current is out-with these tolerances, the cause must be investigated and rectified.
Phase Min (A)
Max (A)
Actual (A)
L1
3.87
4.51
4.3