Falcon DOMINATOR PLUS E3405 Скачать руководство пользователя страница 4

ELECTRICAL RATINGS 

Electrical  loading  is  as  stated  in  table  below  and  also  on appliance data plate. 

The  location  of  mains  isolating  switch  should  be  identified for use in any event of an emergency or during 
cleaning. 

Connection 

A @ 230V 

L1 

4.3 

 

 

 

SECTION 2 - ASSEMBLY and COMMISSIONING 

Note 

The following information should be read as applicable to  the unit being assembled. 

 

ASSEMBLY 

a) Unpack and level appliance  b).Remove all packaging 

 

CONNECTION TO AN ELECTRICAL SUPPLY 

Connect as detailed in Sections 1.3 and 1.4. 

 

 

STARTING UP 

Switch on mains supply. Red neon will light. 

Press switch, amber neon will light 

Ensure both elements heat up. 

 

 

INSTRUCTION TO USER 

After installation and commissioning is completed, please  hand  User  Instructions  to  user  and  ensure  that  the 
person

(s) 

responsible  understands  the  instructions  regarding correct operation and cleaning of the appliance. 

Содержание DOMINATOR PLUS E3405

Страница 1: ...having had a demonstration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY...

Страница 2: ...s Poor combustion caused by lack of cleaning Lubrication of moving parts Lubrication of gas cocks Cleaning adjustment of pilots Correction of gas pressure to appliance Renewing of electric cable ends...

Страница 3: ...type H07RN F If cable is damaged it must be replaced by a suitably qualified person A suitably rated isolating switch with contact separation of at least 3mm in all poles must be installed and wiring...

Страница 4: ...icable to the unit being assembled ASSEMBLY a Unpack and level appliance b Remove all packaging CONNECTION TO AN ELECTRICAL SUPPLY Connect as detailed in Sections 1 3 and 1 4 STARTING UP Switch on mai...

Страница 5: ...nd on off switch To access gantry element remove 10 fixings from around gantry Disconnect element wires then remove securing clip Replace in reverse order To access lower element remove control panel...

Страница 6: ...SECTION 4 SPARES and ACCESSORIES When ordering spare parts please quote model number serial number and voltage stated on data plate Red neon Amber neon On off switch Element ceramic Element tubular...

Страница 7: ...CIRCUIT DIAGRAM L L ON OFF Switch Amber Neon N N E E To Control Panel Tag...

Страница 8: ...WIRING DIAGRAM R6359 7 MAINS CABLE L 1 5 6 10 2 11 N 9 4 3 E 12 R6430 10 11 TO CONTROL PANEL 12 8 9 R7044 1 3 2 4 5 7 6 8 R5530 RV101 RV100 R5219...

Отзывы: