SERVICING WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
22
Conversion to LP Gas
Servicing - warning
This conversion must be performed by a competent person.
After conversion the installation must comply with the relevant
regulations and also the local electricity supply company
requirements. Read the instructions before converting this
appliance.
Failure to convert the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, cooker positioning, connection hose suitability etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and check
appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Conversion
Disconnect from electricity and gas before servicing. Check
appliance is safe when you have fi nished.
This appliance is CAT II2E+3+. It is supplied set for G20 natural
gas at 20millibar
A conversion kit for LP gas (G30 29mbar/G31 37mbar) is
supplied with the cooker.
Injectors
Burner head
Brass venturi
Burner base
Burner ring
Undo the large brass nuts and remove the brass venturis and
brass rings.
Either:-
Use a long box spanner to access and remove the old
jets.
Or: -
Lift up the front of the hotplate top and prop it up. The
burner bases are now accessible - remove the old jets.
Save the jets removed from the appliance for possible future
use. Fit the new jets, see the table for the correct type.
If you have lifted up the hotplate then carefully replace it
taking care not to damage or displace the ignition electrodes
or fl ame safety probes (arrowed) and replace the rear fi xing
screws.
Tap adjustment
Pull off all the control knobs.
Open the oven door & grill door and remove the fi xing screws
underneath the control panel.
Remove the 3 fi xing screws at the top of the control panel.
Pull the control panel forward. Rest it on the open grill door
and the open right hand oven door.
To convert the control taps
Unscrew the tap bypass screw.
Using a pair of long nose pliers carefully remove the bypass
screw and fi t the correct replacement screw. Tighten the screw
down.
Tighten the screw down.
Repeat for all the burner control taps.