![FALCOM TANGO Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/falcom/tango/tango_hardware-description_539615044.webp)
TANGO
VERSION 1.04
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.
Page 43
If you had entered
AT+CGQREQ=1,0,0,3,0,0
then try with
AT+CGQREQ=1,0,0,0,0,0
and vice-versa.
Also, be sure to enter the APN which is case sensitive.
3.3.
Failure to send data after entering an URL
The MS is GPRS attached, the session is successfully open, the
remote dialup connection is running fine on PC but when I enter an
URL in the web browser, nothing seems to happen.
So first of all, double click on dialup connection icon from the tray
bar and check whether the number of sent bytes increases whenever
you enter an URL (and press ENTER).
If that number does not increase there is much likely a routing
problem coming from the PC.
In that case, run the winipcfg tool and check for entries different
from 'PPP adapter' from the combo-list.
If they are so, select them one by one, and for each one hit 'free' to
tell Windows this interface is now down and must done ignored
when routing.