8.
Specifications
Model
VL25F1
Maximum load capacity (kg)
2500
Minimum pickup height (mm)
100
Maximum lift capacity (mm)
1755
Lifting time (s)
<55
Lowering time (s)
>20
Motor power (kW)
2,2
Lift voltage (V)
230
Reach rear telescopic arm (mm)
500 - 661
Reach front telescopic arm (mm)
560 - 863
Measurements lift LxBxH (mm)
2580x2122x2600
Weight(kg)
710
9.
Troubleshooting
Problem
Cause
Solution
Pump does not work
1. Broken fuse/circuit breaker
2. Wrong voltage to motor
3. bad connection in wiring
4. LIFT-button burnt out
5. Motor burnt out
1. Replace fuse/reset circuit
breaker
2. Check voltage
3. Repair and isolate all
connections
4. Replace LIFT-button
5. Replace engine
Motor runs, but lift does
not raise
1. Valve for lowering does not close
2. Pump sucks air
3. Connector for suction broken off
4. Oil level too low
1. Repair or replace valve for
lowering
2. Firmly tighten all couplers for
the oil suction
3. Replace connectors for
suction
4. Fill oil with Falco CH32V oil
Motor raises lift without
load, but not when loaded
1. Motor runs on low voltage
2. Pollution in lowering valve
3. Lift is overloaded
1. Check the voltage
2. clean lowering valve
3. Check the weight of the
vehicle/center the vehicle
Lift lowers slowly
1. Debris in check valve seat
2. Debris in lowering valve seat.
3. External oil leaks
1. Clean check valve.
2. Clean lowering valve.
3. Repair eternal leaks.
Lift raise slowly
1. Air mixed with oil.
2. Air mixed with oil suction.
3. Oil return tube loose
1. Change oil to ISO-32 oil
2. Tighten all suction line
fittings.
3. Reinstall oil return tube.
Locking system does not
work
1. Latch shafts rusted. (Usually
occurs on outside installation or in
high humidity areas such as vehicle
wash bays.)
2. Latch spring broken.
3. Latch cable needs adjustment.
1. Remove covers, oil latch
mechanism. Depress latch
release handle several times to
allow oil to coat shaft.
2. Replace broken spring.
3. Adjust clamps at cable end
per lift installation instruction.