background image

 

 

Page 1 (Inside) 

                                          

 

Please be careful when removing and installing the Island installation Brackets and Stainless 
Steel chimneys. The Stain  Less steel chimneys contains sharp edges and can possibly lead to 
cuts. 

Generally asked Questions and Answers: 

1.  Q: My extractor fan is not extracting  

A: 

before logging a service call please ensure the installation on your extractor fans was done 

properly to avoid a service call out fee charge. Herewith a list of commonly found mistakes on 
everyday installations:  
* Installer did not remove the tape on the butterfly valve. (Q: 13). 

*

Installer did not secure the power cord inside the chimney. (Q: 13). 

*

Your ducting hose is exceeding the recommended maximum length. (Q: 13). 

*

Your unit is not at the recommended height. (Q: 3). 

*

Your unit is installed above the wrong application. (Q: 2). 

  R 450.00 Service fee will apply when we log a service call and any of the points above apply.

                  

 

2.  Q: Can I use the extractor fan above my gas braai?  

A: 

NO. Please note that this unit was designed for the intended purpose of domestic kitchens 

only and cannot be used as a commercial extractor fan. Commercial usage includes but is not 
limited to: Restaurants, Coffee Shops, Soup Kitchens, Tuck shops, Food trailers, Gas 

braai’s 

inside or outside your property, any other form of braai and any kitchen that is used for 
commercial purposes. Using the extractor you purchased on any commercial application 
poses a serious fire risk and will result in immediate void of your warranty.  
 

3.  Q: What is the correct installation height?  

A: 

The recommended installation height is 750mm above gas and 650mm above electrical. 

On either application it is recommended that your installation height does not exceed 750mm 
to ensure the best results.  
 

Q: Do I require a recirculation kit? 
A: 

No. The extractor was designed to be used on both applications; External and Re-

circulation air operation and no additional kit are required.  
 

4.  Q: What is the difference between External and Re-circulation air operation? 

A: Re- circulation; 

All wall mount units are supplied with aluminium and charcoal filters. For 

Re-circulation mode you will simply install the unit. The air will filtrate through both sets of 
filters, you’re outside aluminium filters 

and

 

you’re inside charcoal filters.

 

The air discharged 

from your extractor is then clean and crease free and cannot cause any damage. There are 

 

Содержание FAL-60-22S

Страница 1: ...Cooker hood Instruction manual Model No FAL 60 55RDS FAL 90 55RDS FAL 60 55SLS FAL 90 55SLS FAL 60 52S FAL 90 52S FAL 60 22S FAL 90 22S FAL 90 51SG FAL 90 30SG FAL 60 38SG FAL 90 38SG FAL 90 2245SG ...

Страница 2: ...al extractor fan Commercial usage includes but is not limited to Restaurants Coffee Shops Soup Kitchens Tuck shops Food trailers Gas braai s inside or outside your property any other form of braai and any kitchen that is used for commercial purposes Using the extractor you purchased on any commercial application poses a serious fire risk and will result in immediate void of your warranty 3 Q What ...

Страница 3: ...ed under the guarantee period For the full list of terms and condition of the guarantee period please read the warranty certificate supplied inside the box or in your manual You can also download it from www falco co za 7 Q How often do I have to replace my filters A With daily use we recommend that you replace your charcoal filters every 6 months Your aluminium filters can be cleaned in luke warm...

Страница 4: ...e power cable is neatly secured inside the chimneys and make sure the power cable is not causing an obstruction on top of your butterfly valve Poor workmanship and failure to secure the power cable causes the cable to lie on top of the butterfly valve and this will block and prevent the unit from extracting properly Please ensure that the tape stuck over your butterfly valves in the factory is rem...

Страница 5: ...ditional inline motor when your ducting hose is exceeding 2 5m 14 Q Parts Availability A Full range of spares are available from Lategan Van Biljoens in Pretoria www appliancesspares co za 15 Q What is the diameter of my ducting hose A 150mm 16 Q More Queries A Please email any queries to christie falco co za Tel 011 454 6423 4314 Spares can be viewed and ordered online www appliancespares co za 4...

Страница 6: ...before use 2 The installation work must be undertaken by a qualified and competent fitter 3 The manufacturer disclaims all liability for any damage or injury caused as a result of not following instructions for installation contained in the following text The cooker hood is used on 220 240v 50Hz ...

Страница 7: ...wer low noise electric motor and centrifugal leaf it produces strong suction low noise non stick grease filter and easy to clean 3 With the isolated low voltage circuit board control 12vAC input the lights are therefore safer 4 Special wind tunnel construction and oil collector design free dirt will be absorbed in a second ...

Страница 8: ...the outside chimney bracket on the outside chimney and be sure that the inside chimney can be adjusted the height in it freely as well as fixing the extensible pipe Afterwards install the extensible pipe and chimney on the cooker hood See Pic 3 3 4 Put the cooker hood on the hook See Pic 4 3 5 Adjust the height of the inside chimney to the position of the inside chimney bracket and fix on it by sc...

Страница 9: ...ording to the lead direction and way on the cooker hood and then use the screws to fix the glass also lead the extensible pipe outside of the room meanwhile adjust the height of the inside chimney to the position of the inside chimney bracket and fix on it by screw here should be sure the inside chimney can be flexed freely See Pic 4 3 5 Put the two chimneys together onto the cooker hood body mean...

Страница 10: ...st 2 It cannot share the same air ventilation tube with other appliance such as gas tube warmer tube and hot wind tube 3 The bending of ventilation tube should be 120 parallel or above the start point and should be connected to the external wall 4 After installation make sure that the extractor is level to avoid grease collection at one end ...

Страница 11: ...ult with your cooker hood please call the service department appointed by agent for servicing Please keep the room draughty when your cooker hood and gas hob are working Do not exhaust the gas from cooker hood through the same heated flue which is for the gas from gas hob and other kitchen appliances Before installation and usage read all the instructions and make sure that the voltage V and the f...

Страница 12: ...otor will stop 3 Push the middle button the indicating light 2 on the buzzer will buzz once and the motor runs at mid speed Push it again and the motor will stop 4 Push the high button the indicating light 3 on the buzzer will buzz once and motor runs on high speed Push it again and the motor will stop 5 Push the light button the indicating light 4 on and the two lighting lamps will come on Push i...

Страница 13: ... mid speed 4 Push the High button the buzzer will buzz once and the motor runs at high speed 5 Push the light button and the two lights will come on Push it again and the light will turn off Slide button There are 3 speeds for the motor and on off switch for the lamp Slide the switch for operation Motor Operation 0 off 1 Low Power Setting 2 Mid Power Setting 3 High Power Setting Light Operation 0 ...

Страница 14: ...GH speed Press button again the hood works at LOW speed again and it repeat While pressing button the button is always on If you want to stop the hood now press the button once 4 When the hood is not working press button once The hood will work at the speed it works last time and LCD will show Press button again the hood stop working and will disappear from LCD 5 When both button and button don t ...

Страница 15: ... according to the delay timer you set from 1 minute to 60 minutes Press button once it enters for delay timer setting and LCD shows Press button once the number adds by 01 Continue pressing button it will display from until Press button once the number reduces by 01 After setting delay timer you want press button to confirm If you set delay timer as 05 00 the LCD display will show from 05 00 04 59...

Страница 16: ...nstructed to do so it can be put into a dishwasher set the temperature at around 60 degrees 7 2 Notice of cleaning cooker hood A To protect the main body from corrosion over a long period of time the cooker hood should be cleaned with hot water plus non corrosive detergent every two months B Please do not use abrasive detergent for it will damage the body C Keep the motor and other spare parts fre...

Страница 17: ... tightly sealed Take down the one way valve and seal with glue Leakage from the connection of U shaped section and cover Take U shaped section down and seal with soap or paint Shake of the body The leaf damaged and causes shaking Replace the leaf The motor is not tightly hanged Lock the motor tightly The body is not tightly hanged Fixed the body tightly Insufficient suction The distance between th...

Страница 18: ...r warranty It is an express condition of these warranties that the purchaser takes due care and attention in the use and maintenance of the product appliance 3 Any physical damage to the product appliance that occurred prior to delivery receipt of the product appliance will only be included in this warranty provided that it is reported together with the proof of purchase within 48 hours thereof An...

Отзывы: