FOR INSTALLERS AND PROFESSIONALS
2. INSTALLATION AND MAINTENANCE
The heat pump must be installed by a professional team. The users are not qualified to install by
themselves, otherwise the heat pump might be damaged and risky for users’ safety.
2.1. Notice before installation
:
2.1.1. The inlet and outlet water unions
can’t
bear the weight of soft pipes. The heat pump must be
connected with hard pipes!
2.1.2
.
In order to guarantee the heating efficiency, the water pipe length should be
≤10m
between
the pool and the heat pump.
2.2. Installation instruction
2.2.1. Location and size
The heat pump should be installed in a place with good ventilation
* MINIMUM DISTANCE
Filter
Water processor
Water switch