![Fairhaven Micro Alti 2 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/fairhaven/micro-alti-2/micro-alti-2_manual_3064396015.webp)
PACE of tones - This sets the scale of the vario’s tones. So if you
are generally searching for small amounts of lift, such as when ridge-
soaring, a high setting will make the vario more responsive to small
altitude changes. If, on the other hand, you are used to flying at higher
climb rates, such as when thermalling, a lower setting will be more
useful as the audio tones will vary more gradually over a larger range.
Unit - Allows metric or imperial units to be selected.
1. Metric altimeter and vario in metres per second.
2. Altitude in feet and vario in feet (x100) per minute.
3. Altitude in feet and vario in metres per second.
G-METER AUDIO – Selecting this option (with a press on the right
button) provides a range of tones (similar to the vario) to indicate G
force, providing audible feedback in acrobatics and training. Selecting
VARIO AUDIO reinstates the regular vario tone system.
EXIT - Use left or right buttons to exit.
Middle Sub Menu
The middle sub menu is accessible with a long press on SUB and gives
access to less-used settings, tests, serial number etc. Short presses then
cycle the options below, use left and right buttons to change settings.
DEMO - Sets the Micro Alti to be highly responsive to demonstrate its
operation. Lift tone=30mm/second, Lift finder threshold=1.1m/s, sink
threshold=800mm/s.