FagronLab™ applicator long
FagronLab™ coupling
The FagronLab™ applicator long with a diameter of 2 mm allows formulations to
be introduced into large orifices of the body or probes.
In addition, the applicator long also comes inside each FagronLab™ 200 ml jar to
help pushing up the bottom of this jar size in full.
The FagronLab™ coupling connects two FagronLab™ jars by their screw threads
of their dispensing openings and is very useful when preparing ointments in
larger batches. Transferring a formulation from a larger jar into a smaller jar
using the coupling will ensure hygiene from the mixing process to the end user.
The 200 ml jar becomes a convenient transfer device to smaller jars when their
jar bottoms are carefully pressed towards the work surface using an applicator,
long screwed on a 30 ml jar.
The jar coupling is available as FagronLab™ jar coupling 15 - 1000 ml and
also as FagronLab™ jar coupling 2000 ml.
Pic.: FagronLab™ applicator long
Pic.: FagronLab™ coupling
Pic.: FagronLab™ spindle
FagronLab™ spindle
The FagronLab™ spindle serves as a dispensing system for FagronLab™ jar sizes
300 ml or 500 ml. Extract the spindle from the jar. Push carefully the bottom of
the jar with a disinfected SMB (if not available, with a disinfected spatula) all the
way down.
Air can be diminished by placing the jar with slightly open lid loosely onto a
spindle and pushing the bottom upwards. Before giving the jar to the customer,
the safety adapter needs to be removed and the spindle must be screwed in the
jar counter clockwise from the bottom until it locks into place. The spindle must
be turned clockwise to extract the ointment. One turn dispenses approx. 20 ml
of the contents of the jar.
Caution!
•
If the movable bottom is accidentally perforated or the spindle is permanently locked in the bottom
of the jar, the jar may only serve as dispensing or storage vessel and can no longer be used for the
mixing process.
In addition to the coupling, required for transferring from a 300 ml or 500 ml jar into a smaller jar, both the spindle and the
AirDynamic may also be used. Dispensing and transferring a formulation via the regular jar nozzle from a 1000 ml and 2000 ml jar
is practically only possible using the AirDynamic.
We recommend transferring the formulation after mixing as soon as possible, since the formulation is still warm and less viscous.