background image

FagronLab™ PRO DMS – User Manual  |  6

Items

Qty

Main unit

1

Power cable

1

Magnetic stirrer

1

User manual

1

5. Proper use

Unpacking

Unpack the equipment carefully and check for any 
damages may have arisen during transport. Please contact 
supplier for technical support.

6. Review

Listing of items

The package includes the following items:

The device is specially designed for mixing and/or heating 
liquids in pharmacies, laboratories or factories.

  Observe the minimum distances between the devices, 

between the device and the wall and above the 
assembly (min. 100 mm).

> 100 mm

Figure 1. Minimum distance between the devices

7. Trial and custom use

  Make sure that the required operating voltage matches 

with the power supply voltage.

  Ensure that the socket is properly grounded.

  Plug in the power cable, ensure the power is on and 

begin initializing.

  Add the medium into the vessel with an appropriate 

stirring bar.

  Place vessel on the work plate.

  Set the desirable stirring speed.

  Set the desirable temperature.

  Stop both heating and stirring functions. If these 

operations above are normal, the device is ready for use. 
If these operations are not normal, the device may be 
damaged during transportation, please contact supplier 
for technical support.

  Use a FagronLab™ magnetic rod to remove safely the 

stirring bar from the vessel.

Warning:

  Forbid to transfer the vessel when the 

device working.

FagronLab™ PRO-DMS

Note:

  If there is any apparent damage to the 

system, please do not plug it into the 
power cable.

Содержание FagronLab PRO-DMS

Страница 1: ...FagronLab PRO DMS User Manual www fagronlab com ...

Страница 2: ......

Страница 3: ...l and custom use 6 8 Control 7 Control elements 7 Control panel 7 Display 8 9 Function 8 Heating 8 Working with external temperature sensor 9 Residual heat warning HOT 9 10 Stirring 9 11 Remote control 10 12 Faults 10 13 Maintenance and cleaning 11 14 Associated standards and regulations 11 15 Specifications 12 Table of contents ...

Страница 4: ...ive with the following information Serial number on the rear panel Certification Description of problem Methods and procedures adopted to resolve the problems Your contact information This device is under warranty and free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser...

Страница 5: ...of the Periodic Table of Elements will have chemical reaction with PTFE when temperature reaches 300 400 C Check the device and accessories prior to each use Do not use damaged components Safe operation is only guaranteed with the accessories described in the Accessories chapter Accessories must be securely attached to the device and can not come off by themselves Always disconnect the plug before...

Страница 6: ...e that the required operating voltage matches with the power supply voltage Ensure that the socket is properly grounded Plug in the power cable ensure the power is on and begin initializing Add the medium into the vessel with an appropriate stirring bar Place vessel on the work plate Set the desirable stirring speed Set the desirable temperature Stop both heating and stirring functions If these op...

Страница 7: ...b stir Set the rated rotary speed The function stirring is switched ON or OFF via pushing ON OFF the knob Heating knob heat Set the rated temperature The function heating is switched ON or OFF via pushing ON OFF the knob LCD display LCD displays the real working state and all settings LED heat When the heating function is switched ON the LED Heat is lit LED stir When the stirring function is switc...

Страница 8: ...ature of the sample 9 Function Figure 4 Device display Note If both heating and stirring functions have been started at the same time heating function always has higher priority If in this case speed is changed via the stirring knob it displays stirring speed and reverses to temperature in the duration of 5 seconds Characters Description Temp and C Display temperature when the heating function is ...

Страница 9: ...tically switch off If users want to turn off the LCD immediately just unplug the power cable When the power cable is pulled out the residual heat warning function cannot be visual 10 Stirring The function stirring is switched on or off via pushing the stirring knob The speed can be set by the knob 100 to 1500 rpm in steps of 10 rpm When both of functions heating and stirring are switched on the LC...

Страница 10: ...contact supplier The unit can be controlled from an external PC using the dedicated software via the RS232C serial interface fitted to the unit Data communication from laboratory device to computer is only possible on demand of the computer The functions of the interface lines between laboratory device and automation system are selected from the specified signals of the EIA standard RS232C corresp...

Страница 11: ... and place it in a stable dry room temperature and clean location 13 Maintenance and cleaning Proper maintenance can keep the device working properly and lengthen its lifetime Do not spray cleanser into the device when cleaning Unplug the power cable when cleaning Only use recommended cleansers to maximize the life of your FagronLab PRO DMS device Before using other method for cleaning or decontam...

Страница 12: ...ry speed display LCD Plate material Stainless steel Ceramic coated Dimensions of workplate mm Ø 135 Heating power W 500 Temperature range C RT 340 increment 1 Temperature display C LCD Temperature display accuracy C 0 1 The safe temperature of hotplate C 360 Temperature sensor in medium PT1000 Control accuracy of heating temp with temp sensor C 0 2 Residual heat warning 50 C Device Dimensions LxWx...

Страница 13: ...FagronLab PRO DMS Notes ...

Страница 14: ...FagronLab PRO DMS Notes ...

Страница 15: ......

Страница 16: ...Together we create the future of personalized medicine Fagron Hellas 12 km N R Trikala Larisa P C 42100 P O Box 32 Trikala Greece T 30 24310 83633 5 F 30 24310 83615 www fagron gr P R OD M SU M 0 1 ...

Отзывы: