19 

Use 3/4

” copper tubing inlet line. 

It is necessary to remove all foreign debris from the water line that may potentially get trapped in the 
valves or cause an obstruction, prior to connecting to the machine. 
Use only the supplied hoses (3/4” Female hose connector) at the water connections. Failure to do so 
may result in damage to the solenoid valve threads and leaking. Tighten by hand. Connect the bent 
side of the hose to the machine. Adaptor supplied for ¾” female garden hose connection. 

FOR HARD WATER SUPPLIES WITH A HARDNESS OF OVER 3 gpg OR 5ºfH AND PH BEYOND 
THE RANGE OF 6.5 

– 7.5, A WATER CONDITIONER/DESCALER MUST BE INSTALLED. 

In  addition  to  water  quality,  the  pressure  of  the  mains  water  supply  must  be  considered.  This  is 
important to ensure the machine operates correctly. 

CO models

: Required water dynamic pressure measured at pressure gauge 25psi ± 5psi. 

COP models

: Required water dynamic pressure measured at water inlet between 20-58 psi. 

CAUTION

:

 Do not confuse static pressure with flow pressure. Static pressure is the line pressure in 

a “no flow” condition (all valves and services are closed). Flow pressure is the pressure 
in the fill line when the solenoid valve is opened during the filling or cycle. 

In areas where the pressure fluctuates or it is higher than the recommended pressure, a water pressure 
regulator shall be installed between the shut-off cock and the water hose 

(Fig. 1.). 

If the water pressure is less than required, installation of a water pump is required

The hot water heater should be set to deliver 140 

F (not lower than 122 °F) water temperature to the 

dishwasher  for  best  results,  except  in  hood  type  HRS  models,  where  the  water  inlet  temperature 
should be between 41 ºF and 77 ºF in order for the HRS system to function properly. 

Slowly turn on the water supply to the machine after the incoming fill line and the drain line have been 
installed. Check for any leaks and repair as required. All leaks must be repaired prior to placing the 
machine in operation. 

The following requirements are necessary for the correct hydraulic installation of the machine. 

 

The hydraulic circuit must be fitted with a valve to shut-off the water supply. 

 

Check that the mains pressure is within the range indicated. 

 

To optimise the work of the machine, the water temperature at the machine intake should be 
within the following range: 122 

º

F (50 

C) < Hot water Temp < 140 ºF (60 

C) 

For HRS hood type models: 41 ºF (5 

C) < Water Temp (HRS) < 77 ºF (25 

C). 

 

If using hot water, the water temperature must not exceed 60 

º

C / 140 ºF.

  

 

All the machines should have a 3/4

” screw-on connection. 

 

8.5

 

Drainage connection 

Attach the  drain  hose as shown in Fig.  2.   The drainage pipe must always  be fitted on a  siphon to 
prevent the return of odours. 

All piping from the machine to the drain must be a minimum 1-

1/2” I.P.S. There should also be an air 

gap between the machine drain line and the drain. For natural overflow efficiency use floor drain. 

The water draining from the machine must flow freely and therefore the drainage pipe should be lower 
than the drainage outlet 

(Fig. 2)

 

If the drainage  pipe  is not lower, a drainage  pump will be required. This  must not be  mounted at a 
height of more than 

23 5/8

” 

for hood type dishwashers or 

19 3/4” 

for undercounter dishwashers and 

glasswashers 

(

Fig.  3

)

.  In  this  case,  the  pump  may  be  requested  at  the  time  of  purchase  or 

subsequently.  

 

Fig. 2

. Drainage installation. 

D: Drain hose 
C: Drain collector 

Содержание W Series

Страница 1: ...AL INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE W MODELS MOD COP 174 W COP 504 W CO 502 W CO 500 W CO 402 W CO 400 W CODE 12220401 REV 05 2021 Hood type Dishwasher Undercounter Dishwasher Glasswa...

Страница 2: ...NT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT Model P...

Страница 3: ...PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation The Equipment must be properly maintained and operated in accordance with Fagor s...

Страница 4: ...ic rinse aid dispenser COP MODELS 21 8 8 Detergent dispenser 22 8 9 Recycling 23 9 USE AND MAINTENANCE INSTRUCTIONS 24 9 1 Operation 24 9 1 1 Control panel symbols 24 9 1 2 Switching on the machine 25...

Страница 5: ...RAL MEASUREMENTS AND CONNECTIONS Hood type Dishwasher COP 174 W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equipotent...

Страница 6: ...6 Hood type Dishwasher COP 174 W HRS A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equipotential bond...

Страница 7: ...Dishwasher CO 500 W CO 502 W COP 504 W Glasswasher CO 400 W CO 402 W A B C D E F G Water inlet Drain hose Power Supply Cable Strain Relief Connection Strip Inside Rinse aid inlet Detergent inlet Equi...

Страница 8: ...8 3 QUICK STARTUP GUIDES...

Страница 9: ...9...

Страница 10: ...10 4 ELECTRICAL DIAGRAM...

Страница 11: ...11...

Страница 12: ...4 Power On Light RT Tank Heating Element H5 Effi rinse Light S1 S2 S3 Program Cycle Push button HC Boiler temperature Display S4 ON OFF Push button HT Tank Temperature Display S5 Lack of salt switch K...

Страница 13: ...ny other objects must not be washed in the machine If your machine breaks down please call the Technical Service Centre Unqualified or unauthorised personnel must NOT try to repair the machine Use of...

Страница 14: ...WASH MIN TEMP HEATING ELEMENTS OPERATING CYCLE TIME s MODEL PUMP MOTOR WASH RINSE WASH TANK kW BOILER kW WASH DWELL RINSE HRS TOTAL COP 174W HRS 1 hp 156 F 180 F 4 9 3 25 13 1 8 7 39 59 104 584 5 11...

Страница 15: ...ll Power 3Ph 240V 17 35 6 74 2 72 0 64 3 05 6 10 CO 502W 208 240V 208V 24 34 5 06 2 36 0 48 2 29 4 58 COP 504W 60Hz 220V 25 74 5 66 2 50 0 54 2 56 5 12 Full Power 1Ph 240V 28 08 6 74 2 72 0 64 3 05 6...

Страница 16: ...55 AWG 6 MCA 54 MOP 60 CO 502W COP 504W 208 240V 60Hz 3Ph 208 240V 60Hz 1Ph 208 240V 60Hz 1Ph 208 240V 60Hz 1Ph BRIDGE Boiler Full Power Boiler Full Power Boiler 2 3 Power Boiler Half Power AWG 12 MCA...

Страница 17: ...d The machine should be moved using a fork lift truck or similar to avoid damage to the structure Transport the machine to the installation location and then remove packaging All the packaging can be...

Страница 18: ...es are installed in line they should all be ground bonded at the point provided for that purpose To access the connection strip when a permanent connection needs to be made release the cover of the ma...

Страница 19: ...est results except in hood type HRS models where the water inlet temperature should be between 41 F and 77 F in order for the HRS system to function properly Slowly turn on the water supply to the mac...

Страница 20: ...ovide you visible mean that chemicals are being dispensed Operation This dispenser absorbs the rinse aid when it detects a loss in pressure during rinsing That is when the filling solenoid valve close...

Страница 21: ...at optimum conditions it is requested to remove lime and corrosion deposits on a frequent basis A de liming solution should be available from your chemical supplier Read and follow all instructions on...

Страница 22: ...h Temperature Low Suds Liquid Detergent Fagor doesn t recommend any specific brand name of chemicals Contact your local chemical distributor for questions concerning your chemical needs Installation t...

Страница 23: ...All the packaging used around the machine can be recycled The correct disposal of these products will help to protect the environment For further information regarding the recycling of these products...

Страница 24: ...able options 9 1 1 Control panel symbols CO 400W Glasswasher CO 500W Front Loading Dishwasher CO 402W Glasswasher CO 502W COP 504W Front Loading Dishwasher COP 174W COP 174W HRS Hood Type Dishwasher O...

Страница 25: ...that in the event of the breakdown of any of the main thermostats the safety thermostats switch off the corresponding heating During the first heating of the day the boiler may reach a higher tempera...

Страница 26: ...cycle The wash cycle selected by default is P2 in machines with more than one wash cycle button Each wash cycle corresponds to a wash time that should be selected according to the user requirements Wh...

Страница 27: ...ng care not to burn yourself as the dishes are extremely hot 9 1 7 Drainage of the machine The dishwashers have two types of drainage gravity drainage or using a drainage pump which is optional 9 1 7...

Страница 28: ...tableware inside the machine from being cleaned properly 9 1 9 Cleaning the machine at the end of the day At the end of the day the filters wash distributors rinse branches and other accessories must...

Страница 29: ...your technical service to protect the machine against frosts 10 FAULTS ALARMS AND BREAKDOWNS The steps to be followed in the event of a fault or operating error are described below The possible cause...

Страница 30: ...rinse aid Call technical service to adjust rinse aid dispenser Water too chalky Check water hardness Machine stops during operation Electrical installation overloaded Call technical service to modify...

Страница 31: ...ting failure E6 TH E6 Tank Heating WARNING on display Draining error After 2 minutes with drain cycle the level of the tank has not dropped E7 DR E7 Drain Machine disabled The boiler does not fill Aft...

Страница 32: ...Fagor Commercial Inc 13105 NW 47th Avenue Miami FL 33054 USA T 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...

Отзывы: