Power line connection
POWER LINE CONNECTION
Cho
ke
6.
Ref.2003
· 211 ·
QC-PDS
HARDWARE
Changing the orientation of the chassis support
Connecting the chassis to ground protection
Selection
Table
indicates the appropriate CHOKE for the main regenerative
power supply model installed in the system.
For more information on the technical data of the CHOKES, see section,
. Also refer to its dimensions in section,
.
F. H6/8
CHOKE RPS-160. Orienting the chassis support.
F. H6/9
CHOKE RPS-160. Chassis to ground protection.
T. H6/5
Selecting the CHOKE.
POWER SUPPLY
CHOKES
QC-PS-025
Not applicable
QC-PS-045
Not applicable
QC-RPS-030-F
CHOKE RPS-45
QC-RPS-160-
CHOKE RPS-160
1. LOOSEN THE FOUR M3x8 SCREWS
2. ROTATE THE CHASSIS SUPPORT 180 ° AND
TIGHTEN THE FOUR M3x8 SCREWS
TURN THE CHASSIS SUPPORT 180º TO MAKE THE CONNECTION OF THE
SHIELDS EASIER AND BETTER SETTLE THE CABLES
0.7 N·m
S/2
t
PE
M8 SCREW OF
PROTECTIVE
EARTH
CHASSIS TO PROTECTIVE EARTH
TO THE
PROTECTIVE
EARTH CENTRAL
POINT
Содержание QC-PDS
Страница 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Страница 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Страница 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Страница 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Страница 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Страница 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Страница 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Страница 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Страница 322: ...Connection diagrams 10 CONNECTION DIAGRAMS 322 Ref 2003 QC PDS HARDWARE 322 This page intentionally left blank...
Страница 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Страница 367: ...ANNEXES...
Страница 368: ...ANNEX A1...
Страница 383: ...ANNEX A2...
Страница 398: ...ANNEX A3...
Страница 418: ......
Страница 419: ......