MCSi-58/84
Digital Brushless AC servo drive system - Ref.0707
Function:
Determines the analog function assigned to the programma-
ble analog input.
Valid values:
0, ..., 2.
Default value:
0.
Function:
Monitors the voltage through the analog input ANALOG
VELOCITY COMMAND INPUT (VEL+ and VEL-) (pins 2 - 1
of X3). It's display is in volts.
Function:
Monitors the input voltage through analog input 2 (pins 18 -
17 of X3). It's display is in volts.
Function:
Contains the value of the auxiliary analog command (pins 17
and 18 of X3; usually current command) after being affected
by CP10 and CP11. It must never exceed the value of the
maximum current of the unit.
Valid values:
- 50.00, ..., + 50.00 Arms.
Default value:
0.
IP17
USER, RW
AnalogFunctionSelector
IP17
Function
IV3
as input
to function Nr
00
--------
01
Func1
02
Func2
IV1
BASIC, RO
AnalogInput1
IV2
USER, RO
AnalogInput2
IV3
USER, RO
CurrentCommandAfterScaling
VEL +
X3.2
VEL
-
X3.1
IV1
16 Bit
X3.18
X3.17
IV2
12 Bit
X3.19
PROG. ANALOG. INPUT
X3.19