5.2.1
Description of the controls
Mr control
Ma control
5.2.2
Burner ignition
•
Pilot ignition:
o
Turn the
Mr energy control anticlockwise to the "max" position. Now lamp “L1” lights up,
indicating that the pilot is ready to be lit (above figure).
o
Next press the solenoid valve control M, while turning it anticlockwise to the pilot position
. Hold the control pressed in this position until the pilot flame remains lit
(approximately 20 seconds).
•
Burner ignition:
o
Pressing the solenoid valve control M, turn it to the Burner ignition position, as the Mr
control is in "max" position, the burners will light.
o
The
“L2” lamp indicates that the burners are operating.
o
Turn the Mr control to the required position.
o
In the Bain Marie models, the pressure of the chamber should rise until reaching 0.4
Kg/cm. Once this value has been reached, the appliance automatically adjusts the
pressure of the chamber.
5.2.3
Turing the burners off
•
Turn the M valve control to the position Pilot
, only the pilot will be lit.
5.2.4
Turning the pilot light off
•
Turn the M valve control to the Off position .
•
Turn the Mr energy control to the Off position .
5.2.5
Filling the pot with water
To fill the pot with water, turn the water fill control Ma to the required position (cold water
or hot
water
).