7
O
Otth
he
err IIn
ns
stta
alllla
attiio
on
n R
Re
eq
qu
uiirre
em
me
en
ntts
s
Y
Yo
ou
urr c
co
oo
ok
k--tto
op
p m
mu
us
stt a
allw
wa
ay
ys
s b
brre
ea
atth
h a
ad
de
eq
qu
ua
atte
elly
y.. M
Ma
ak
ke
e s
su
urre
e tth
ha
att tth
he
e a
aiirr iin
nlle
ett a
an
nd
d iitts
s
e
ex
xh
ha
au
us
stt a
arre
e n
no
ott o
ob
bs
sttrru
uc
ctte
ed
d..
T
Th
he
e u
un
niitt m
mu
us
stt n
no
ott b
be
e iin
ns
stta
alllle
ed
d a
ab
bo
ov
ve
e a
a w
wa
as
sh
hiin
ng
g m
ma
ac
ch
hiin
ne
e,, a
a rre
effrriig
ge
erra
atto
orr o
orr a
a d
de
ee
ep
p--
ffrre
ee
ez
ze
err b
bo
ox
x
T
To
o e
elliim
miin
na
atte
e tth
he
e rriis
sk
k o
off b
bu
urrn
ns
s o
orr ffiirre
e b
by
y rre
ea
ac
ch
hiin
ng
g o
ov
ve
err h
he
ea
atte
ed
d s
su
urrffa
ac
ce
e u
un
niitts
s,, c
ca
ab
biin
ne
ett
s
stto
orra
ag
ge
e s
sp
pa
ac
ce
e llo
oc
ca
atte
ed
d a
ab
bo
ov
ve
e tth
he
e s
su
urrffa
ac
ce
e u
un
niitts
s s
sh
ho
ou
ulld
d b
be
e a
av
vo
oiid
de
ed
d..
T
Th
he
e u
un
niitt m
mu
us
stt b
be
e iin
ns
stta
alllle
ed
d s
su
uc
ch
h tth
ha
att iitt c
ca
an
n b
be
e p
pu
ulllle
ed
d w
wiitth
ho
ou
utt d
diiffffiic
cu
ulltty
y o
ou
utt o
off tth
he
e c
cu
utt--o
ou
utt
ffo
orr s
se
errv
viic
ciin
ng
g o
orr c
clle
ea
an
niin
ng
g..
N
Ne
ev
ve
err g
gllu
ue
e,, s
siilliic
co
on
ne
e o
orr w
we
ed
dg
ge
e tth
he
e u
un
niitt iin
ns
siid
de
e iitts
s c
cu
utt--o
ou
utt..
During cooking, built-in fan inside the
cooktop will operate constantly to keep the
internal components cool. The air intake is
on the bottom of the cooktop box, and the
warm air exhaust is located on the back of
the rim, as shown on the schematic. If the air
intake or the exhaust is obstructed, the
cooktop safeties will either diminish the
power output or shut down the unit.
We suggest that you should periodically
check that there are no objects (dust, paper,
etc.) which could obstruct the air inlet under
your induction cooktop.
Although induction-cooktop heat rejection is
minimal and the unit does not create any
fumes in operation, such unit must be
installed underneath a properly sized
ventilation hood for exhausting any smell,
vapor and smoke created by cooking itself.
Also, a proper downdraft system can be
used for ventilation.
A minimum vertical clearance of 750 mm
[30”] is required between the top of the
cooking surface and the bottom of any
unprotected combustible material, such
as cabinets, wooden trim etc.
In the back, leave a minimum of 10 mm
[3/8”] between the cooktop edge and
adjacent vertical surfaces (backsplash,
wall, high cabinets etc.). This space is
needed for the unit to breath properly.
If a downdraft ventilation system is used,
a minimum of 6 mm (1/4”) of clearance
is required between the rear edge of the
cooktop and the downdraft snorkel.
Leave a minimum of 50 mm [2”]
underneath the unit for the air intake.
Air
Intake
Exhaust
Cabinet Above
Cabinet Belo
w
40 [1 5/8"
]
Minimum
Clearance
Requirements
Cross
Section
750 mm (30
”)
50 mm (2
”)
Cabinet below
Cabinet Above
750 mm 30”
10 mm
[3/8”]
Cross section
Minimum
Clearance
Requirements
50 mm 2”
Exhaust
Air
Intake