Electrical connection 

The  appliance  is  profited  to  operate  with  a  power 
supply voltage of 230Vsingle-phase. The connection 
must be made in accordance with the regulations and 
laws in force. 
Before making the connection, make sure that: 
1)

 

the  safety  circuit-breaker  and  the  electrical 
system  are  able  to  withstand  the  load  of  the 
appliance(see nameplate). 

2)

 

The  power  supply  system  has  an  earth 
connection in good working order in accordance 
with the regulations in force; 

3)

 

The  socket  or  omni  polar  switch  use  are  easily 
accessible with the appliance installed. 

Fit a plug suitable for the load on the power lead and 
connect it to a suitable safety socket. 
If you wish to make a direct connection to the mains, 
an  omni  polar  switch  with  a  gap  between  the  contacts  of  at  least  3  mm,  of  suitable 
rating  for  the  load  and  complying  with  the  regulations  in  force,  must  be  installed 
between  the  appliance  and  the  mains.  The  switch  must  not  break  a  contact  in  the 
yellow/green earth wire. 
The  brown  live  wire  (connected  to  the  “L”  terminal  of  the  terminal  board)  must 
always be connected to the live wire of the power supply mains. 
In  all  cases,  the  power  supply  lead  must  be  positioned  so  that  it  does  not  reach  a 
temperature 50

o

C above the room temperature 

at 

any point. 

One  example  of  an  ideal  route  is  shown  in  the  illustration.  The  cable  is  guided  by 
means of band clamps fixed to the side of the cabinet, in order to avoid any contact 
with the appliance underneath the hob.   
 

Replacing the power supply lead 

If  the  lead  has  to  be  replaced,  only  HO5RR-F  or 
HO5RN-F  type  cables  suitable  for  the  load  and  the 
operating  temperature  must  be  used.  In  addition,  the 
yellow/green  earth  wire  must be about  2  cm  longer than 
the live and neutral wires.   
 
                                                                                                                                    11 

 

Содержание Hob

Страница 1: ......

Страница 2: ...accident prevention regulations Make sure that air is able to circulate freely around the appliance Poor ventilation produced a shortage of oxygen Make sure that the appliance is supplied with the type of gas indicated on the relative sticker next to the mains gas connection pipe Use of a gas cooking appliance produces heat and moisture in the room in which it is installed Ensure that the room is ...

Страница 3: ...o not find the necessary information contact your nearest Service Centre Servicing work on this appliance must be carried out by an authorized Technical Service Centre Always request the use of original spare parts Environmental protection advice All the materials used are environmentally compatible and recyclable Please make your contribution to conserving the environment by using the separate wa...

Страница 4: ...o fitted kitchen units 13 Guide to reading the instructions The following symbols will help you When reading the instructions Safety information Step by step instructions Suggestions and Advice Information concerning environmental protection This appliance complies with the following EEC Directives 73 23 and 90 683 relating to Low Voltage 89 336 relating to Electromagnetic Compatibility 90 396 rel...

Страница 5: ...ttings and never between the maximum setting and the closed position Symbol present on version with lighting A Burner cap integrated in the Control knob B Lighting plug C Thermocouple D Triple flame cap Dual triple flame version no gas flow maximum gas flow from central burner minimum gas flow from central burner maximum gas flow from outer and central burners simultaneously minimum gas flow from ...

Страница 6: ...a flame near the burner and proceed as already described If the flame does not light after a few attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the control knob clockwise to the symbol Before removing pans from the burners always lower or turn off the flame For correct use of the hob For lower gas consumption and better efficiency Use only flat...

Страница 7: ...arm water and a little liquid detergent Do not use the following products household detergents or bleaches soaped scouring pads not suitable for non stick utensils steel wool scouring pads stain removers for baths or sinks If the hob gets very dirty use specific commercial products Ignition plug Automatic burner ignition is provided when installed by a ceramic plug and a metal electrode B in fig 1...

Страница 8: ...r who sold you the appliance or our nearest Service Centre specifying the nature of the problem the model of the equipment Mod the product number Prod No and the serial number Ser No These data are provided in the plate on the cover of this manual Always request the use of original spare parts Warranty conditions You new appliance is covered by a warranty The warranty conditions are provided in fu...

Страница 9: ...5 0 362 0 98 277 0 77 277 Gas intake connection G1 2 Electricity supply 220 240v 50 60Hz Instructions for the installation technician CAUTION This appliance must only be installed and used in rooms with permanent ventilation to local standards Installation of the appliance and its connection to the electrical mains must only be carried out by QUALIFIED PERSONEL Before any procedure it is important...

Страница 10: ...liance is installed the necessary air may be taken from an adjacent room provided that this room is not a bedroom or a hazardous environment this room has ventilation the ventilation between the room where the appliance is installed and the adjacent room has openings Discharge of flue gases Gas cooking appliances must discharge their flue gases through hoods connected directly to flues or the outd...

Страница 11: ...nion must be fitted on the end of the gas train Complete with GJ1 2 threaded nut fitting the gasket between the components as shown in the illustration The gaskets must comply with the local standards Screw the parts together without forcing fit the union so that it points in the direction required then tighten all parts Connection Make the connection to the gas system using a rigid metal pipe and...

Страница 12: ... at least 3 mm of suitable rating for the load and complying with the regulations in force must be installed between the appliance and the mains The switch must not break a contact in the yellow green earth wire The brown live wire connected to the L terminal of the terminal board must always be connected to the live wire of the power supply mains In all cases the power supply lead must be positio...

Страница 13: ...fied or variable a suitable piped gas pressure regulator complying with the standard must be installed on the supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn the tap to the minimum flame position 3 Remove the control knobs 4 Use a thin straight screwdriver to turn the by pass pin located next to the tap rod see fig B For LPG turn the by pass pin fully clock...

Страница 14: ...in the installation opening place the special gasket around the bottom edge of the hob It is important to fix this gasket evenly without gaps or overlapping to prevent liquid from seeping underneath the hob 1 Remove the pan stands and the burner caps and turn the hob upside down taking care not to damage the ignition plugs and the thermocouples 2 Place the gasket around the bottom edge of the hob ...

Отзывы: