background image

www.fagorcommercial.com

 

Page

 

 

MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015

 

4

 

INSTALLATION 

 

 
4.1

 

UNCRATING 

 
Remove the outer packaging. 

Cut the 4 clamps that hold the refrigerator to the skid. Lift 

the unit off the skid.

 

 

If  machine  was  laid  down  during  this  operation,  remember  to  leave  the 
cabinet up right for 24 hours before connecting to power source. 

 

4.2

 

LOCATION 

 
Units represented in this manual are intended for indoor use only. Be sure the location 
chosen has a floor strong enough to support the total weight of the unit and its contents. 
For  the  most  efficient  operation,  be  sure  to  provide  at  least  three  (3)  inches  between 
sides, back and top of the unit.  

          

                   THE MACHINES NEEDS TO BE INSTALLED 2 FEET AWAY FROM ANY HEAT SOURCES

.  

 

The unit should not be installed under ambient temperatures higher than 100 °F.  
If the relative humidity is higher than 60 %, the door frames may sweat water. This is 
not a malfunctioning of the unit.  

 

WARNING  

The following actions will void your warranty: 

 

Modification of power cord. 

 

Connecting the unit to any extension cord. 

 

Neglecting to install the castors or optional legs.

 

 
Inside cabinet: 
The first cleaning must happen when you unpack the unit and before it is turned ON. 
For  this,  you  have  to  clean  the  unit  with  warm  water  and  mild  detergent.  When  it  is 
cleaned and dry, proceed to install accessories and plug your unit into a dedicated outlet. 

WAIT 24 HOURS BEFORE PLACING PRODUCT IN THE UNIT

. This will guarantee that it is 

working properly. 

Consequential damages are not covered under warranty. 

 
Outside cabinet: 
Be sure that the unit has access to ample air to breathe. Avoid hot corners and locations 
near  stoves  and  ovens.  It  is  recommended  the  unit  be  installed  no  closer  than  3”  from 
any  wall.  The  place  where  the  refrigerator  is  placed  must  be  open  and  clean.  This  will 
reduce the amount of debris and dirt on the condenser fan and coil.  

 

Содержание FMD-49

Страница 1: ...MERCHANDISER REFRIGERATORS AND FREEZERS Manual for installation use and maintenance...

Страница 2: ...TIONS 4 3 DIMENSIONS 6 4 INSTALLATION 9 4 1 UNCRATING 9 4 2 LOCATION 9 4 3 DATA PLATE 10 4 4 ELECTRICAL CONNECTIONS 11 4 5 SHELVING INSTALLATION 11 5 OPERATION 12 5 1 ELECTRONIC CONTROLLER 12 6 MAINTE...

Страница 3: ...material until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines...

Страница 4: ...tion Line Super Heat BTU Ref Amount Ref Type Ship Weight Set Point Cut in FM 10 10 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1400 9 8 oz R 134a 203 FM 16 16 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1800...

Страница 5: ...2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 10 AWG 12 AWG FM 16 1 4 115 220 5 8 3 4 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12...

Страница 6: ...www fagorcommercial com Page6 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 3 DIMENSIONS FM 10 FM 16...

Страница 7: ...www fagorcommercial com Page7 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 23 FDM 49...

Страница 8: ...www fagorcommercial com Page8 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 47 SD FMD 37 SD...

Страница 9: ...ity is higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to a...

Страница 10: ...it The data plate is essential to identify the particular features of your machine and it is of great benefit to installers operators and maintenance personnel It is recommended that in the event the...

Страница 11: ...ordance with NEC Article 422Appliances DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine is still...

Страница 12: ...ontroller The display will light up showing the temperature inside the unit Also the compressor and fan icons will flash for a period of three minutes After this delay the unit will start cooling Veri...

Страница 13: ...to save the new set point Note The maximum value you can set in the controller is For refrigerators 5 C 40 F 3 If you wish decrease the value of the set point for a new temperature press the button DO...

Страница 14: ...ters Type F parameters include the set point differential temperature monitoring interval interval between defrosts end defrost temperature dripping time alarm thresholds alarm bypass times etc See th...

Страница 15: ...y the Parameter belongs to see the table below and the parameter table 5 Press the SET button to display the value of the parameter 6 Press UP DOWN until reaching the desired value 7 Press Set to temp...

Страница 16: ...nless steel surface Failure to do so will result in spots and rust on the surface affected 6 1 CLEANING THE CONDENSER COIL DANGER Power must be turned off and disconnected from the power source whenev...

Страница 17: ...ket and rip the bellows Gaskets can easily be replaced and do not require the use of tools or authorized service personnel To remove the gasket pull the gasket towards you To replace gasket press the...

Страница 18: ...nit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of the unit and the evaporator coil will freeze up Do not store hot products...

Страница 19: ...www fagorcommercial com Page19 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 7 WIRING DIAGRAMS FM 10...

Страница 20: ...www fagorcommercial com Page20 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16 FMD 23...

Страница 21: ...www fagorcommercial com Page21 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16F FMD 23F...

Страница 22: ...the maximum level mark located on the internal wall of the unit f If FREEZER check that the temperature is not Celsius C g Check that the gasket is in good condition and door is sealed h Check that th...

Страница 23: ...will be replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warr...

Страница 24: ...d waived unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have t...

Страница 25: ...in deliveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted...

Страница 26: ...fagorcommercial com Page26 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 GO FAGOR www fagorcommercial...