Power line connection
6.
Ref.1912
· 233 ·
DDS
HARDWARE
6.6 Line inductance
Line inductance means including chokes on each of the three power lines.
Its function is to reduce the harmonics generated in mains. The
recommended value is given by the formula:
To simplify the choice, we could consider optimum the values given in the
following table:
When not installing the mains filter, we recommend to use the line
inductance in order to minimize disturbances, although is warned that this
inductance does not guarantee the compliance with the CE seal.
T. H6/6
Line inductance selection according to the power supply or
compact drive installed.
PS-25B4
PS-65A ACD|SCD|CMC
1.08 | 1.15
ACD|SCD|CMC
1.25
L (mH)
1
0.4
5
3
Irms (A)
40
100
11
18
L
V 0.04
2
f I
rms
--------------------------
=
MANDATORY.
Do not install line chokes in line with RPS or XPS
regenerative power supplies. They generate interference in the
regenerating mechanism.
Содержание DDS Series
Страница 1: ...DRIVE DDS Hardware manual Ref 1912...
Страница 6: ...6 Ref 1912 DDS HARDWARE 6 I This page intentionally left blank...
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 16: ...Ref 1912 DDS HARDWARE 16...
Страница 20: ...Ref 1912 DDS HARDWARE 20...
Страница 179: ...3 Drives Ref 1912 179 DDS HARDWARE...
Страница 180: ...3 Drives Ref 1912 DDS HARDWARE 180...
Страница 200: ...4 AUXILIARY MODULES Auxiliary modules Ref 1912 DDS HARDWARE 200...
Страница 260: ...7 Cables Ref 1912 DDS HARDWARE 260...
Страница 397: ...Sales models 12 Ref 1912 397 DDS HARDWARE 12 9 Order example F H12 21 Order example...
Страница 404: ...13 Compatibility Ref 1912 DDS HARDWARE 404...
Страница 405: ......