Fagor AD - 21 W Скачать руководство пользователя страница 15

 

For

 

Customer

 

Service:

 

Call

 

1

866

GO

 

FAGOR

 

 

www.fagorcommercial.com

 

|

  

P.

 

15

 

 
 
 
 
 
 
 
 
 

SYMPTOM 

POSSIBLE CAUSE 

ACTION 

Dishwasher RUNS 

continuously in the wash 
cycle or not rinsing. 

Faulty Circuit Board  

Make sure power is being supplied to the board. Check 
for loose wiring harness connections. Check circuit board 
fuse. Check voltage between R (brown) and N (blue). If 
208V-240V found, replace circuit board. 

Dishwasher RUNS 

continuously in the wash 
cycle or not rinsing. 

Faulty Circuit Board  

Make sure power is being supplied to the board. Check for 
loose wiring harness connections. Check circuit board 
fuse. Check voltage between R (brown) and N (blue). If 
208V-240V found, replace circuit board. 

Faulty Operating t-stat 

(Tc)/Faulty Circuit Board 

Verify rinse gauge temperature is above 180°F. If above, 
replace circuit board. If rinse temperature <180°F replace 
Tc thermostat and/or boiler element and heater relay. If 
A4 is displayed, reconnect temperature sensor. If A5 is 
displayed, replace temperature sensor.  

Faulty rinse/fill valve (V) 

Verify the wiring and correct voltage at valve; if correct 
replace fill valve. 

No water to machine. 

Verify hose is not blocked or kinked. Verify the inlet water 
pressure is at a min of 20 psi and max 25 psi. 

Clogged or obstructed 

rinse arms 

Remove and clean rinse arms/nozzles. 

 
 
 
Dishwasher FILLS slowly 

and/or rinse is weak. 

Poor water pressure 

Verify the inlet water pressure is at a min of 20 psi and 
max 25 psi. 

Hose strainer is clogged 

Check strainer or any filters installed. 

Bad rinse/ fill valve (V) 
Valve can be clogged 

causing poor flow. 

Disconnect hose from fill valve and check filter screen 
inside for debris. Replace rinse/fill valve as needed. 

Temperature gauge in 

front panel is defective. 

Check temperature with a calibrated thermometer at the 
corresponding temperature sensor location. Replace 
temperature gauge as needed. 

Dishwasher RUNS. 

RINSE WATER NOT 
REACHING MINIMUM 
TEMPERATURE OF 180°F 

Misadjusted/faulty 

thermostat (Tc) 

Verify rinse temperature probe sensor is properly inserted 
inside probe well. Replace Tc thermostat and/or boiler 
element and heater relay. If A4 is displayed, reconnect 
temperature sensor. If A5 is displayed, replace 
temperature sensor. 

Faulty high limit stat (Tl) 

Reset thermostat by depressing red button. Replace if 
necessary. Make sure  heater  relay (Cc) is working 
properly (not stuck in or out) and Tc thermostat is cutting 
off below 195°F  

Faulty  heater  relay (Cc) 

Verify voltage at heater relay coil (A1, A2), solenoid 
closes when receiving voltage. If not, replace heater relay 
(Cc). 

Faulty Boiler element (Rc)   Ohm out element check for continuity; if open, replace 

heater (Rc). 

Содержание AD - 21 W

Страница 1: ...SERVICE MANUAL 2013 UNDERCOUNTER GLASSWASHER UNDERCOUNTER GLASSWASHER Models AD 21 W...

Страница 2: ...EQUESTED QUALITY OF THE WATER 7 WATER DRAINAGE INSTALLATION 7 ELECTRICAL CONNECTION 8 INSTALLATION CHECKLIST 9 OPERATION 9 TURNING THE MACHINE ON 10 PREPARING THE MACHINE 10 WASHING 10 COOL RINSE 11 D...

Страница 3: ...s 15 Flow rinse pressure 20 25 psi Total Time Seconds 3 settings 60 90 180 Wash Pump Motor Dimensions Shipping Motor hp 1 3 HP Width 20 508 mm Depth 24 1 2 622 mm Temperatures Height 34 1 2 876 mm Was...

Страница 4: ...amage should be noted and reported to the delivering carrier immediately If damaged open and inspect the contents with the carrier In the event that the exterior is not damaged yet upon opening there...

Страница 5: ...maintenance personnel It is recommended that in the event the data plate is removed you copy down the essential information in this manual for reference before installation Any transformations or chan...

Страница 6: ...noid valve is opened during the cycle THE DISPLAY OF THE PRESSURE GAUGE SHALL BE CLEARLY VISIBLE OF THE OPERATOR OF THE MACHINE THE GAUGE SHALL HAVE INCREMENTS OF 1 psi 7 kpa OR SMALLER AND SHALL BE A...

Страница 7: ...the machine Adaptor supplied for female garden hose connection FOR HARD WATER SUPPLIES WITH A HARDNESS OF OVER 2 GRAINS OR 10 F AND PH BEYOND THE RANGE OF 7 0 8 5 A WATER CONDITIONER MUST BE INSTALLED...

Страница 8: ...d from the rear to facilitate cleaning of the location of the glass washer Install a circuit breaker according to required consumption guidelines Page 1 and data plate The machine must be grounded Fig...

Страница 9: ...__ F Is the water hardness 2 0gpg 34 2ppm and PH level 7 8 5ph Has the drain plumbing been installed according to the instructions in this manual Height of the drain hose ______ Air gap size _______ W...

Страница 10: ...ures are displayed before putting the machine to wash WASHING NOTE All models are fitted with Thermo stop The temperature of the incoming water should be higher than 120 F 50 C Ideal temp 140 F 60 C I...

Страница 11: ...it should be drained after each meal rush Draining the Machine Open the door and remove the Front Right S S Filter leave door open Fig 8 Remove the overflow tube by inserting a finger into the top of...

Страница 12: ...ed Detergent and place inside detergent container Take the tube with a blue stripe mark and place inside rinse container Tubes are clear to provide you a visible means that chemicals are being dispens...

Страница 13: ...de down Put cutlery in the cutlery baskets handles down Mix spoons with knives and forks Fig 10 Put the special cutlery baskets in the base baskets Fig 10 Fig 11 DELIMING In order to maintain dishwash...

Страница 14: ...e at terminal 2 brown and GND If no voltage P1 is possible stuck Faulty rinse fill valve V Verify the wiring and proper voltage at valve if correct replace fill valve Dishwasher will NOT RUN after the...

Страница 15: ...ax 25 psi Clogged or obstructed rinse arms Remove and clean rinse arms nozzles Dishwasher FILLS slowly and or rinse is weak Poor water pressure Verify the inlet water pressure is at a min of 20 psi an...

Страница 16: ...or damaged replace pressure switch P2 Machine temperatures or pressure may not be to specification Wait until sanitized rinsing temperature reached a min of 180 F Check out your incoming water temper...

Страница 17: ...ile the drainage pump does not drain the water in the tank to the correct level in the specified time 4 Flashes BOILER HEATING ERROR This is indicated by a four flashes and a pause This continues whil...

Страница 18: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 18 ELECTRICAL DIAGRAM...

Страница 19: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 19 WIRING SCHEMATIC...

Страница 20: ...V 16A 50 60 HZ Z393005 Boiler thermostat Z400709 Washing nozzle Z400711 Washing nozzle bracket Z401001 Pump motor 60Hz Z421711 Boiler heating element 2800W Z433011 Pressure switch Z393005 Tank thermos...

Страница 21: ...between 25 and 2 0 grains per gallon pH level between 7 0 8 5 and TDS level at 250 PPM Equipment failure due to inadequate water supply is not covered by this Warranty Proper Maintenance and Operation...

Страница 22: ...For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 22 Fagor Commercial Inc 13105 NW 47th Ave Miami Fl 33054 Tel 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com...

Отзывы: