version, an air deflector is placed on the superior part of the pipe which allowing air to be 

recirculated.  
 

* In ventilation mode (Fig.2), fumes are directly vented outside, through an evacuation duct 
connected with the superior part of the wall or the ceiling. Utilizing both the charcoal filter and air 

deflector are not necessary in this case. 
 

3.

 

Installation

  

Before installing the appliance, make sure that no parts are damaged. In case of damaged parts, 
contact your retailer and do not proceed with installation. Read all of the following instructions with 

care before installing the appliance. 
 

- Use an air outlet pipe of the shortest possible length. 
 

- Limit the number of bends in the pipe. 
 

- Use only materials approved by safety standards and regulations. 
 

- Avoid sudden changes in pipe section (recommended diameter minimum: 6 inches (150 mm) or 
equal surface area). 

 
This hood has been designed in order to position the air outlet towards the upper rear side of the 

appliance. In case you want to position the air outlet towards the rear side, it is necessary to 
remove the no. 10 screws of the suctioning unit support (Fig.13), then take the suctioning unit out, 

by rotating it in such a way to position the air outlet nozzle towards the rear side of the appliance 
(Fig.13); then place the suctioning unit back into its position, and re-insert the previously removed 

screws. 

 

Wall

 

Mounting:

 

 

 

Using the drilling jig supplied (dis. 3A). Drill the holes for the wall bracket installation (Fig.3B); the  

hood must be positioned 

at a minimum of 16 inches (40 cm) 

from the cooktop.  Mount the brackets 

on the wall using the screws supplied and hang the hood. 

4) on the bracket previously mounted. Using the adjustment screws (fig. 5) make sure 
the hood is horizontally well aligned. Lift the front panel upwards, as shown in Fig. 6. Remove the 

grease-filter. 
 

In connection with the holes indicated by the arrows in Fig. 7a-7b, drill two 8 mm diameter holes 
into the wall, and insert the screw anchors supplied with the appliance. Screw in the screws 

supplied with the appliance, in order to further secure the appliance to the wall; place the grease 
filter back into its seat and close the front panel. 

 
 

 
 

 

Содержание 5CFB36BL

Страница 1: ...CARE INSTRUCTION MANUAL BLACK CRYSTAL WALL MOUNTED HOOD 5FCB 36 BL Note To avoid accident and damage please read these instructions carefully before operating the appliance ...

Страница 2: ...gistration card included This manual contains complete information about the recommended installation as well as use care of this product Please read this manual carefully before installing or operating the Black Crystal Hood to ensure proper usage and maintenance Carefully following the directions in this booklet will enable you to optimize the performance and lifespan of the unit If you have any...

Страница 3: ...ted by a person responsible for their safety Air should never be ventilated by this appliance through or into a duct used to let out fumes from appliances fed by energy other than electric power eg centralized heating radiators water heaters etc Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow ...

Страница 4: ...lease make sure that the current tap is provided with earth connection and that voltage values correspond to those indicated on the label placed inside the appliance itself The use of materials which can burst into flames should be avoided in close proximity of the appliance When frying please pay particular attention to fire risk due to oil grease Since it is highly inflammable fried oil is espec...

Страница 5: ...u want to position the air outlet towards the rear side it is necessary to remove the no 10 screws of the suctioning unit support Fig 13 then take the suctioning unit out by rotating it in such a way to position the air outlet nozzle towards the rear side of the appliance Fig 13 then place the suctioning unit back into its position and re insert the previously removed screws Wall Mounting Using th...

Страница 6: ...n turning it down until it is fixed inside Recirculation mode In recirculation mode the air deviator is fixed through the screws supplied Fig 10 by using the holes which are on the back of the upper telescopic section Connect the flange of the appliance with the air deviator through an appropriate pipe Connect the appliance with the electric mains Lift the lower pipe until the cable strap coming o...

Страница 7: ...used in recirculation mode the active charcoal filter Fig 8 needs to be periodically replaced The filter can be removed by removing the grease filter first and by pulling its special plastic tongue until it is unfastened from its slot Re insert the filter by operating in the opposite way The charcoal filter needs replacing depending on the use but recommended every six months at least Before repla...

Страница 8: ...ncidental or consequential damages so this exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state IF YOU NEED SERVICE Please contact Customer Care at Fagor America at 1 877 743 2467 or email Fagor America at infoappliances fagoramerica com IMPORTANT NOTICE PLEASE COMPLETE AND MAIL THIS WARRANTY RE...

Страница 9: ...located inside the hood under the filters PLACE STAMP HERE FAGOR AMERICA APPLIANCES DIVISION P O BOX 94 LYNDHURST NJ 07071 FAGOR AMERICA INC PO BOX 94 LYNDHURST NJ 07071 Toll Free 1 800 207 0806 Email infoappliances fagoramerica com www fagoramerica com The manufacturer reserves the right to modify the items described in this manual ...

Страница 10: ...Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 ...

Страница 11: ...Fig 7 a Fig 7 b Fig 8 Fig 9 Fig 10 Fig 11 ...

Страница 12: ...Fig 12 Fig 13 Fig 14 ...

Отзывы: