1. Important Safeguards 
2. 

Recirculation

 

&

 

Ventilation

 

 

3. Installation 
4. Operation  
5. Maintenance 
6. Warranty  

 

 

1.

 

Important

 

Safeguards

 

 

To reduce the risk of fire, electric shock, or injury while operating this  
hood, please observe the following:  

 

• This unit is intended for domestic household use. Be sure to use and install this unit only in 

accordance with the manner for which it is intended.  

 

• Installation work and electrical connections must always be carried out by qualified person(s) in 

accordance with all applicable codes and standards, including fire-rated construction. 
 

• Be sure to switch off power prior to cleaning or servicing this unit.  
 

• 

This appliance is not intended to for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and/or knowledge operating household 

appliances, unless they are carefully supervised or instructed by a person responsible for their 
safety. 

 

 

Air should never be ventilated by this appliance through or into a duct used to let out fumes from 

appliances fed by energy other than electric power (eg. centralized heating, radiators, water-
heaters, etc.).  

 

• Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) 
of fuel burning equipment to prevent back drafting.  

 
• Follow the heating equipment manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), and the American Society for 
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and your local code authorities. 

 
• Before cutting or drilling into walls or the ceiling, be sure to first inspect areas around, above & 

below the area to ensure that damage to electrical wiring or other potentially hidden utilities does 
not occur. 

 
• Use only metal ductwork to reduce the risk of fire.  Additionally, ducting must always be vented to 

the outdoors to reduce the risk of fire. Do not vent the exhaust through ceilings, attics, crawl 
spaces, garages or behind walls.  

 

Содержание 5CFB36BL

Страница 1: ...CARE INSTRUCTION MANUAL BLACK CRYSTAL WALL MOUNTED HOOD 5FCB 36 BL Note To avoid accident and damage please read these instructions carefully before operating the appliance ...

Страница 2: ...gistration card included This manual contains complete information about the recommended installation as well as use care of this product Please read this manual carefully before installing or operating the Black Crystal Hood to ensure proper usage and maintenance Carefully following the directions in this booklet will enable you to optimize the performance and lifespan of the unit If you have any...

Страница 3: ...ted by a person responsible for their safety Air should never be ventilated by this appliance through or into a duct used to let out fumes from appliances fed by energy other than electric power eg centralized heating radiators water heaters etc Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow ...

Страница 4: ...lease make sure that the current tap is provided with earth connection and that voltage values correspond to those indicated on the label placed inside the appliance itself The use of materials which can burst into flames should be avoided in close proximity of the appliance When frying please pay particular attention to fire risk due to oil grease Since it is highly inflammable fried oil is espec...

Страница 5: ...u want to position the air outlet towards the rear side it is necessary to remove the no 10 screws of the suctioning unit support Fig 13 then take the suctioning unit out by rotating it in such a way to position the air outlet nozzle towards the rear side of the appliance Fig 13 then place the suctioning unit back into its position and re insert the previously removed screws Wall Mounting Using th...

Страница 6: ...n turning it down until it is fixed inside Recirculation mode In recirculation mode the air deviator is fixed through the screws supplied Fig 10 by using the holes which are on the back of the upper telescopic section Connect the flange of the appliance with the air deviator through an appropriate pipe Connect the appliance with the electric mains Lift the lower pipe until the cable strap coming o...

Страница 7: ...used in recirculation mode the active charcoal filter Fig 8 needs to be periodically replaced The filter can be removed by removing the grease filter first and by pulling its special plastic tongue until it is unfastened from its slot Re insert the filter by operating in the opposite way The charcoal filter needs replacing depending on the use but recommended every six months at least Before repla...

Страница 8: ...ncidental or consequential damages so this exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state IF YOU NEED SERVICE Please contact Customer Care at Fagor America at 1 877 743 2467 or email Fagor America at infoappliances fagoramerica com IMPORTANT NOTICE PLEASE COMPLETE AND MAIL THIS WARRANTY RE...

Страница 9: ...located inside the hood under the filters PLACE STAMP HERE FAGOR AMERICA APPLIANCES DIVISION P O BOX 94 LYNDHURST NJ 07071 FAGOR AMERICA INC PO BOX 94 LYNDHURST NJ 07071 Toll Free 1 800 207 0806 Email infoappliances fagoramerica com www fagoramerica com The manufacturer reserves the right to modify the items described in this manual ...

Страница 10: ...Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 ...

Страница 11: ...Fig 7 a Fig 7 b Fig 8 Fig 9 Fig 10 Fig 11 ...

Страница 12: ...Fig 12 Fig 13 Fig 14 ...

Отзывы: