Digital Brushless AC servo drive system - Ref.0707
MCSi-77/84
There is short-circuit at the drive module.
Reset the error.
If it persists, may be because:
An erroneous sequence when connecting the power cables or a short-
circuit between them.
The parameters may be wrong or there is a fault at the drive.
Contact Fagor Automation.
After displaying E.214, it will display some of the codes that describe the
type of short-circuit that has taken place.
The hardware of the drive module has detected that the voltage at the
power bus is too high.
When using an external Ballast, it is not connected properly. The Ballast
resistor is burned.
Disconnect the power supply and ckeck the proper connection of the
Ballast circuit.
The mains voltage is too low.
Disconnect the power supply and check the proper condition of the lines.
Due to the duty cycle, the Ballast resistor is overloaded.
Resize the Ballast resistor.
Decrease the duty cycle.
Smooth the duty cycle by applying acceleration ramps.
E.214
Short-circuit
ABS
over the absolute value of the output current
IGBT
at the IGBT's
OUT
in the output
E.304
Power bus voltage too high
E.307
Power bus voltage too low
E.314
Ballast overload