Digital Brushless AC servo drive system - Ref.0707
MCSi-51/84
Default value:
0.
Function:
Display the value of the feedback of the current going through
phase V.
Valid values:
- 50, ...+ 50 A (instant values).
Default value:
0.
Function:
Display the value of the feedback of the current going through
phase W.
Valid values:
- 50, ...+ 50 A (instant values).
Default value:
0.
Function:
Display the rms current circulating through the motor.
Valid values:
0, ..., 50 Arms (rms values).
Default value:
0.
3
External analog.
It applies the value of the external auxiliary input
( pins 17 and 18 of connector X3 ) after being
treated, IV3, if IP17 has the right value (IP17 = 1).
CV1
USER, RO
Current1Feedback
CV2
USER, RO
Current2Feedback
CV3
USER, RO
CurrentFeedback
CP45
From the velocity loop
From the functions generator
Digital Command
IV3
Analog Command
IP17
0
1
2
WV5
CV15
WV4
1
2
3
0
1
2
0
CURRENT
READING
CV1
AD
_sin
CV2
CV10
CV11
IW
IV
_cos