STOP
#
#
English
20 EN
The water doses for coffee and the hot water doses can
also be set using the "SELF-SETTING' function:
press and hold the STOP button for at least 8 seconds
or until you hear a buzzer sound that will keep sounding
throughout the programing. The menu below will appear
on the display, showing the keys with the relative quantities
for water for the coffee.
Coffee measures
1 - Fill the
¿
lter-holder with the required dosage of ground
coffee and insert it in the dispenser unit.
2 - Put the cup or container under the
¿
lter-holder spouts
and press the button to be programed. Keep it pressed
until the desired level is reached in the cup or container.
During this phase, the setting for the volumetric dosage
pulses (top right of display) is increased. When the
key is released, the setting reached is memorized and
appears under the programmed key.
3 - Starting from step 1, continue programing, as desired,
on all the coffee buttons.
Programming measures using the “SELF-LEARNING” function
Hot water measures
1 - Press the button to be programed and keep it pressed
until the desired level is reached in the cup.
During this phase the time in seconds (top right of
display) is increased; when the key is released, the
setting reached is memorized and appears below the
programmed key.
2 - Starting from step 1, continue programing, as desired,
on all the water buttons.
When
¿
nished, press the STOP button. The buzzer will
turn off, thus con
¿
rming that the programing has been
completed.
SELF-LEARNING
Group 1
DV: 000
090 150 080 160
STOP
SELF-LEARNING
water buttons
t: 3.5
3.5 5.0
STOP
02_EmblemaR_1442.indd 20
21/10/2014 09:41:35
Содержание Emblema R