English
43 EN
MALFUN.
CODE
VERIFICATIONS and SOLUTIONS
P
OSSIBLE CAUSES
DESCRIPTION
Group x boiler heating
timeout - 20 minutes
(x = 1, 2, 3, 4)
Note: Group 1 is to the far left.
Steam thermocouple out of
range.
DX > 053; SX > 153
Boiler overpressure alarm.
Boiler: Refill timeout
- 15 minutes.
Boiler-level signal errors.
Coffees dispensed for MM1
with flow under the limit
(3 consecutive coffees
dispensed).
Coffees dispensed referred
to MM1 with flow over the
limit
(3 consecutive coffees
dispensed).
Coffees dispensed referred
to MM2 with flow under the
limit
(3 consecutive coffees
dispensed).
Coffees dispensed referred
to MM2 with flow over the
limit
(3 consecutive coffees
dispensed).
(x)52*
(x) 53*
058
059
060
062
063
064
065
• The group x boiler safety
thermostat has been
triggered
• The resistance is
interrupted (cabling defect).
• Triac board fault.
• Thermocuple
disconnected
• Wrong configuration
during standard data in-
sertion.
• Resistanc
alwayspowered.
• Temperature sensor out
of range.
• No water
• Refill EV failure
• Wiring interrupted
• Card failure.
• Electrical fault.
• Leakage to earth.
• coffee filter blocked
• coffee type changed
• qref calibration wrong
• grind too fine,
excessive dose ground.
• coffee type changed
• qref calibration wrong
• grinding too coarse
• grinder/dispenser
blocked, insufficient
dose of ground coffee.
• coffee filter blocked
• coffee type changed
• qref calibration wrong
• grind too fine,
excessive dose ground.
• coffee type changed
• qref calibration wrong
• grinding too coarse
• grinder/dispenser
blocked, insufficient
dose of ground coffee.
• Check if the safety thermostat of the group x boiler
has been triggered, and reset it if necessary
• Check if there are interruptions or detached
fastons on the cabling
• Check that the group x boiler resistance is not
interrupted and replace it if necessary
• Replace Triac board.
• Enter in the programming mode and insert the
correct standard data..
• Check connections.
• Replace the steam temperature probe.
• Check cabling
• Replace the sensor.
• Check water is supplied from the main line.
• Replace the refill EV.
•Check cabling.
• Replace the card.
• Check wiring.
• Check, by activating the components individually
on the manual control panel, that the level signal
does not show any anomalies (%).
• wash the group
• clean/replace the coffee filter
• use a coarser grind
• calibrate the machine correctly on the basis of
the coffee/recipe.
• check that there are no external elements in the
grinders
• check that the measure grinder is working (pick-
up current and fuses)
• use a finer grind
• calibrate the machine correctly on the basis of
the coffee/recipe.
• wash the group
• clean/replace the coffee filter
• use a coarser grind
• calibrate the machine correctly on the basis of
the coffee/recipe.
• check that there are no external elements in the
grinders
• check that the measure grinder is working (pick-
up current and fuses)
• use a finer grind
• calibrate the machine correctly on the basis of
the coffee/recipe.
Содержание E71 E
Страница 2: ...I 1 14 15 15 12 3 16 5 2 2 15 Tsn 6 6 7 PRG 11 4 3 4 3 4 13 10 9 8 12 17 19 18...
Страница 52: ...English 47 EN 14 Cup Warmer 1 2 3...
Страница 53: ...English 48 EN 15 Stainless steel front panel 1 2...
Страница 54: ...English 49 EN The back panel may be removed only after the cup warmer has been removed 16 Rear panel 1 2 3...
Страница 55: ...English 50 EN 17 Draining the boiler water...
Страница 57: ...English 52 EN 20 Coffee boiler 0 6 mm...
Страница 58: ...English 53 EN 21 display panel...
Страница 59: ...English 54 EN 22 Junction Box 23 Safety thermostat 1 4 3 2 1 4 2 3...
Страница 61: ...English 56 EN FUSE BATTERY Battery Fuse CR 2032 3V CR 2032 3V...