9
Drwg. No.
4333
1
2
Button switch:
3
4
5
6
Photocells and Safety Edge:
12 13
PHOTOCELLS AND
SAFETY EDGE
24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
Push Button Switch Pulin 3:
26
27
28
3
COMMON
Led to indicate status
of Open - Stop - Close
switches
RS RS
Connect a 12VAC
Relay (T4 Trimmer
Time from 2s to 255s)
to operate a 230V
lamp
Electric lock:
RS RS
Set the T4 Trimmer Time
to the lowest value The
electric lock is excited
for 2 seconds
7
3
LOW VOLTAGE ELECTRICAL CONNECTIONS
1
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it on closing once obstacle is
removed
OFF: Photocells do not stop gate while
opening, reverse it on closing in
case of an obstacle
STOP
COMMON
OPEN
CLOSE
Limit switch:
10
COMMON
8
9
LIMIT SWITCH
CLOSE
LIMIT SWITCH
OPEN
Radio Contact:
COMMON
RADIO
CONT
ACT
- Open/Close (Standard)
- Travel reversing on
pulsing
- Step by step
2
5
ON: Step by step. Stop in between
OFF: Standard operating mode
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
DIP-SWITCH 2 and 5 (NEVER set BOTH of
them to ON at the same time):
Light
ON
= Open gate
Light
OFF
= Closed gate
Flashing
(fast) 0.5s
= Closing gate
Flashing
(normally) 1s
= Opening gate
Flashing
(slowly) 2s
= gate is stopped
24V 3W Indication Light:
3
11
Courtesy light:
Flashing lamp:
19 20
230V MAX 25W
4
Power supply:
Single- and Three-
phase Motors:
ELECTRIC POWER CONNECTIONS
-
+
T1
MOTOR RUN TIME
OPEN / CLOSE
from 5 to 128s
T2
-
+
DWELL TIME
from 5 to 128s
7
230V
400V
CAPACITOR
18
16
17
COMMON
M
MOTOR
U
W
V
230V 50Hz SINGLE-
PHASE
21
22
NEUTRAL
S
LIVE
23
22
DIP-SWITCH 4 and 7:
21
22
T
R
S
LIVE
23
22
ON: Pre-flashing
OFF: No pre-flashing
ON: Lamp is not operating during
Dwell Time. Automatic Mode.
OFF: It flashes during Dwell Time.
Automatic Mode.
400V 50Hz THREE-
PHASE
Hold on switched (Deadman) control:
Pedestrian Opening:
Trimmer T3
-
+
OPERATING MODES
from 3 to 30s. It can be activated by
any pulse (eg. by remote control)
superior to 2s
3
DIP-SWITCH 3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
Automatic / Semiautomatic:
Automatic Operation:
any pulse opens the gate, the gate stays
open as long as the Dwell time expires as set by T2 trimmer, then
it closes automatically, no pulsing is required.
Semi-automatic Operation:
any pulse opens the gate that stays
open. A second pulse to Close is required for the gate to close.
Open and Close operations are achieved "by holding a
switch on" (no relay self-holding is involved) therefore a
phisical attendance is required to keep the gate opening
or closing until either the button or key is released.
Remote Controlled Operations Excluded
during Dwell Time on Automatic Mode:
3
ON= Automatic Closing
OFF= Closing by Pulse
5
ON: Step by step. Stop in between
OFF: Standard Operations
With this setting it is not possible to operate the gate by remote control during the dwell time on automatic mode.
DIP-SWITCH 2=ON, 3=ON and 5=ON
DIP-SWITCH 6
6
ON= Deadman Control. Dip-switch 4=OFF
and Dip-switch 3=OFF
OFF= Standard Operations
How it works: Set the clock to the required time. On the pre-set time the gate is automatically opened and held open. Any further pulsing (even
by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time
the gate is closed automatically.
T3 trimmer on to zero, Dip-Switch 3=ON.
DIP-SWITCH No.3=ON Automatic Closing
Time clock:
3
ON= Automatic Closing
OFF= No Automatic. Semi-automatic
closing by pulse
4
3
COMMON
COMMON
OPEN
NO
-
+
Pedestrian Trimmer
T3
set on to zero
2
ON: No reversing on opening
OFF: Travel reversing on any pulsing
Dwell Time
from 5 to 128s
T2
-
+
COMMON
OPEN
4
3
LIVE
LIVE
Содержание VIGILO 2250
Страница 1: ...FITTING INSTRUCTIONS GB ...