manualshive.com logo in svg
background image

Anti-terrorism retractable oil-hydraulic bollard

!

!

!

!

INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM

1)  Installation  operations,  testing,  analysis  of  the  risks  and  future  maintenance  are  to  be  executed  by  quali ed  and 
authorized technicians in compliance with the existing regulations (www.fadini.net/supporto/download).
2) This automatic system is intended to be exclusively used for the applications described in this manual, including at least 
the minimum safety, command and signalling accessories as required.
3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.
4) Providing a suitable reinforcement metallic framework ensures that the breakout resistance value be respected as stated 
in this manual. 

NOTE

: the iron framework (all of the steel rebars) is not supplied by our company. It has to be made locally in 

compliance  with  the  technical  data,  drawings  and  all  of  the  indications  described  in  this  installation  manual.  The 
components  of  the  structure  developed  in  this  way  are  able  to  make  the  most  of  the  performance  features  of  each 
component and ensure the impact resistance features of the bollard as indicated.
5) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system.
6) Make sure the site is free from utilities that may interfere with the installation.
7) Make sure that electromagnetic sources are at a suitable distance from the accessories, especially from the loop
detectors. The magnetic  elds of other sources may affect the detection of the loops as well as those of other
command and safety devices of the system.
8) Make sure the power supply to the electric motor is 230 V (50 Hz).
9)

 Recommended power supply cable: BUT FLESSIBILE FG 7OR 12x1,5 mm² up to 20 metres max.

Ground cable to have a section as required to comply with the site regulations.

10) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
11) The installer shall provide the  nal user with information related to all of the operating commands and functions of the 
system, including that concerning lowering of the post in case of an emergency (manual release operation).
12) The installer shall inform the  nal user of the dangers coming from the presence of persons, especially children, in the 
proximity of the bollard.
13) The manufacturer reserves the right to change this manual without previous notice.

As far as con guration and execution of the system are concerned, these are to comply with the laws in the country of 

installation.

Meccanica  Fadini is not liable  for any  possible damages derived from incorrect use or from any use not 

indicated in this manual, furthermore it is not answerable for malfunctioning caused by the use of materials 

or accessories not approved by the company itself.

It is to be noted that the product respects the impact and breakout resistance values as indicated provided 

that the installation of the same is carried out in observance of the speci cations included in this manual of 

instructions. Various  factors  are  to  be  carefully  taken  into  consideration  such  as  compaction  index,  soil 

permeability coefficient, concrete type, which may affect the indicated values even signi cantly.

This symbol indicates that a particular attention is required on the installation phases and on running 

the operator. Failure to observe these indications may cause incorrect functioning of the bollard.

PRODUCT SPECIFICATIONS

Fully retractable automatic bollard for heavy duty applications, certi ed and tested according to ASTM F2656-15 C750, PAS 
68:2013 V/7500 (N3)/80 standards and IWA 14-1:2013 V/7200 [N3C]/80 standards; made up of two oil-hydraulic motor pump 
units incorporated in the structure and one oil-hydraulic actuator inside the rising cylinder. Designed to stop a vehicle of 7,5 
t at a speed of 80 km/h and remain perfectly intact and operative for the protection of sites under risk of attack and all those 
areas where a high level of security and perimeter protection are required in case of a terrorist assault. IP 67. The height of the 
rising cylinder (from ground) is 1.000 mm. Rising cylinder made of S355K2H steel, thickness 20 mm, cataphoresis treated and 
powder coated. AISI 304 brushed stainless steel cover sleeve available for the rising cylinder. Rubber ring on rising cylinder 
head  with  12  signalling  LEDs  with  ashing  light.  Cataphoresis  treated  aluminium  cover,  nished  to  provide  a  slip-proof 
treading surface. Rising cylinder  tted with high intensity, microprismatic, retrore ecting approved sticker (h 80 mm). Hot 
dip galvanized steel casing for ground foundation. Impact resistance 700.000 J, breakout resistance 2.000.000 J. static load 
max 2.800 kg in standing position, max 20.000 kg in lowered position. Working temperature -40 °C +80 °C. Supply voltage 
230 Vac ± 10%, 50 Hz. Absorbed power 3.100 W. Connector and junction box IP 66 for cabling. Rising time ~ 5,0 s. Frequency 
of use 2.000 cycles/day. Hydraulic device locking the bollard in standing position.

19

Содержание TALOS M50

Страница 1: ...fully retractable post Certified and tested in compliance with ASTM F2656 15 C750 former K12 PAS 68 2013 V 7500 N3 80 IWA 14 1 2013 V 7200 N3C 80 GB Instructions manual pages the gate opener EN 13241...

Страница 2: ...y to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on the gate warning about the presence of an automated installation The installer...

Страница 3: ...providing protection in case of accidental impacts with pedestrians etc and 12 LEDs flashing The foundation casing is made of treated steel hot dip galvanized while the structure of the inner assembl...

Страница 4: ...to gather in it and be pumped out of the bottom of the main pit by a submersed pump Lay a 50 mm 1 9 in corrugated tube suitable for the electric cables required to operate the bollard to be pulled th...

Страница 5: ...omer Nevertheless to allow that a few running tests to assess functioning are carried out before the installation it is possible to access the inner terminal board with the electrical connections by r...

Страница 6: ...sions in millimeters margin of tolerance of 0 5 cm 1 9 in The bollard is to be positioned and levelled on plane before casting concrete around the foundation cage The steel framework is to be class B4...

Страница 7: ...r cage 785 30 9 in 16 0 62 in n 4 pcs per cage 50 1 9 in n 2 lateral cages 200 7 8in 250 9 8 in 810 31 8 in 1 515 59 6 in 470 18 5 in English Anti terrorism retractable oil hydraulic bollard 7 140 5 5...

Страница 8: ...entire steel framework can be made by steel wire or welding nos 14 Transverse rectangular rebar rings 1 650 64 9 in 3 000 118 1 in 650 25 6 in 615 24 2 in English Joining of the cages and of the entir...

Страница 9: ...framework can be made by steel wire or welding pic 11 pic 12 900 35 4 in 1 600 62 9 in 1 600 62 9 in 600 23 6 in 16 0 62 in n 6 pcs n 3 pcs n 3 pcs 16 0 62 in n 3 pcs nos 3 Longitudinal rebars nos 3...

Страница 10: ...made by steel wire or welding pic 13 600 23 6 in 600 23 6 in 600 23 6 in 300 11 8 in 16 0 62 in n 6 pcs n 3 pcs n 3 pcs n 3 pcs 16 0 62 in n 3 pcs n 3 Reinforcing bars for the external side English A...

Страница 11: ...n 0 0 0 0 finished road level finished road level 1 2 cm 5 10 cm 850 33 4 in 1620 63 7 in Anti terrorism retractable oil hydraulic bollard Concrete features A Class C25 30 10 30 aggregates and Rck val...

Страница 12: ...eristics of the place of installation OPENING THE PROTECTION COVER PLATE Remove all the screws to be able to pull away the plate and then access the bollard inside for the electrical connections A wat...

Страница 13: ...F while L13 LED is ON If this does not happen swap connections to terminals 11 and 12 on the Elpro S50 control board L12 Limit switch Opening M3 normally ON it is off with post in down position L13 Li...

Страница 14: ...GAP BETWEEN THE POST AND PLATE IS UNIFORM ALL AROUND The protection plate must seat perfectly onto the entire surface and adhere also to the circular flange all around the post GREASE NOTE WELL IT IS...

Страница 15: ...ing operations are to be carried out Pull away the aluminium cover plate after having removed all the fixing screws Insert the release spanner in the slit on the right into the release device having a...

Страница 16: ...ight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs...

Страница 17: ...Anti terrorism retractable oil hydraulic bollard 17...

Страница 18: ...ectronic board controlling the bollard s e g ooded relay contacts oxidized terminal clamps etc Check the correct functioning and positioning of the limit switches Check the release system for bollard...

Страница 19: ...hange this manual without previous notice As far as con guration and execution of the system are concerned these are to comply with the laws in the country of installation Meccanica Fadini is not liab...

Страница 20: ...in 230 V 50 Hz out 12 Vdc 600 mA Led lights 12 Vdc Post material S355K2H steel Impact resistance 700 000 J Crash resistance 2 000 000 J Maximun static load 20 000 kg Weight complete with casing 770 k...