Dip-B N°1=ON
27
meccanica
FADINI
27
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz
ELECTRICAL CONNECTIONS ON SLIDING GATE MODE - Dip Switch B n°1=ON
RED
YELLOW
GREEN
Power supply
230V 50Hz
Red
Yellow
Green
Red
Yellow
Green
1A Fuse
Common
63 64 65 66 60 61
(
Optional:
Traffic lights
plug-in card for
230V Lamps)
Item
7282L
Traffic lights plug-in card (Optional - Item No. 7282L):
The power supply of this card is independent from that of the control board:
230V 50Hz with an output of 100W at 230V each lamp.
Logic of operation
:
-
GREEN
light
= driveway
OPEN
-
RED
light = driveway
CLOSED
-
YELLOW
light = it switches on before light changes from green to red
Note
: In
Pedestrians
mode the traffic light is always
RED
.
Dip-Switch A
4= ON
Pre-flashing Enabled: traffic lights Red - Yellow - Green
4= OFF
Pre-flashing Disabled: traffic lights Red - Green
6= ON
Limit switches installed
6= OFF
Limit switches linked out (functioning by time setting)
Dip-Switch B
3= ON
Pre-flashing time prolonged by about 2 seconds
(yellow light up to 3 seconds)
3= OFF
Standard time as factory-preset
Functioning with 2 lamps (Red and Green):
Dip-Switch A
4 = OFF
Dip-Switch A
6 =
adjust setting depending on whether the limit switches are
used or not in the installation
Dip-Switch B
3 = OFF
Accessory
Electrical connections
LED indication of functions
Double sliding gate limit switches:
L30 ON
= OFF on engaging L.sw. Opening M1
L31 ON
= OFF on engaging L.sw. Closing M1
L33 ON
= OFF on engaging L.sw. Opening M2
L34 ON
= OFF on engaging L.sw. Closing M2
Single sliding gate limit switches:
Power connections
to Pulin 3 LEDs:
Terminals for
the connections
of the LEDs of the
push buttons
Pulin 3
28
26
27
OUTPUT
24Vdc - 5W max
3
24Vdc-5W output:
29 30
+
-
L30 ON
= OFF on engaging L.sw. Opening
L31 ON
= OFF on engaging L.sw. Closing
L33 ON
= OFF on engaging L.sw. Opening
L34 ON
= OFF on engaging L.sw. Closing
30 31 32 33 34
common
M1
M2
Opening
Limit switch
Closing
Limit switch
Opening
Limit switch
Closing
Limit switch
30 31 32 33 34
comune
Opening
Limit switch
Closing
Limit switch
In applications where only one motor is fitted,
connect the inputs of the M1 and M2 limit
switches be put in "parallel" (bridge 30 with 33
and 31 with 34, and then connect them to the
limit switches Open - Close).
IMPORTANT:
if
no limit switches
are involved,
link out terminals 30 - 31 - 32 - 33 - 34.
Limit switches ( L-sw.) must have normally
closed contacts.
In applications where two motors are fitted, connect the
normally closed limit switches to the respective input terminals.
IMPORTANT:
if
no limit switches
are involved, link out terminals
30 - 31 - 32 - 33 - 34. Limit switches ( L-sw.) must have normally
closed contacts.