2013/06
I
DATI TECNICI
Tensione di alimentazione
230 V - 50 Hz
Tensione motore
24 Vcc
Potenza assorbita max.
150 W
Corrente assorbita max.
5 A
Coppia massima
180 Nm
Tempo apertura-chiusura (95°)
16 s
(15 s con guida scorrevole)
Grado di protezione
IP 53
Lubrificazione
grasso
Temperatura di lavoro
-20°C +50°C
Peso Bart 350 Master
10 Kg
Peso Bart 350 Slave
6,5 Kg
Frequenza di lavoro massima consentita 30 cicli/ora
Limiti d’impiego
Peso massimo anta
250 kg (max. 1,5 m)
Lunghezza massima anta
2,3 m (max. 200 Kg)
F
E
t
D
1
NL
Via Mantova, 177/A - C.P. 126 - 37053 Cerea (VR) Italy
Tel.+39 0442 330422 r.a. - Fax +39 0442 331054
e-mail: [email protected] - www.fadini.net
La Ditta costruttrice si riserva di apportare modifiche al presente libretto senza preavviso.
DONNÉES TECHNIQUES
Tension d’alimentation
230 V - 50 Hz
Tension moteur
24 Vcc
Puissance absorbée max
150 W
Courant absorbé max
5 A
Couple maximum
180 Nm
Temps ouverture-fermeture (95°)
16 s
(15 s avec rail de guidage)
Degré de protection
IP 53
Lubrification
graisse
Température de travail
-20°C +50°C
Poids Bart 350 Master
10 Kg
Poids Bart 350 Slave
6,5 Kg
Fréquence de travail maximum autorisée 30 cycles/heure
Limites d’utilisation
Poids max. vantail
250 kg (max. 1,5 m)
Longueur max. vantail
2,3 m (max. 200 Kg)
DATOS TÉCNICOS
Tensión de alimentación
230 V - 50 Hz
Tensión del motor
24 Vcc
Potencia máx. absorbida
150 W
Corriente máx. absorbida
5 A
Par máximo
180 Nm
Tiempo apertura-cierre (95°)
16 s
(15 s con guía corrediza)
Grado de protección
IP 53
Lubricación
grasa
Temperatura de funcionamiento
-20°C +50°C
Peso Bart 350 Master
10 Kg
Peso Bart 350 Slave
6,5 Kg
Frecuencia de funcionamiento máxima permitida
30 ciclos/hora
Limites de utilizo
Peso maximo hoja
250 kg (max. 1,5 m)
Maxima longitud de hoja
2,3 m (max. 200 Kg)
L’entreprise de construction se réserve le droit d’apporter des modifications à ce manuel
sans préavis.
La empresa fabricante se reserva el derecho de aportar modificaciones al presente manual
sin previo aviso.
TECHNICAL SPECIFICATIONS
Electrical power supply voltage
230 V - 50 Hz
Motor power supply
24 Vdc
Power absorbed max
150 W
Current absorbed max
5 A
Maximum torque
180 Nm
Opening-closing time (95°)
16 s
(15 s with sliding guide )
Degree of protection
IP 53
Lubrication
grease
Operational temperature
-20°C +50°C
Bart 350 Master weight
10 Kg
Bart 350 Slave weight
6.5 Kg
Maximum permitted operating frequency 30 cycles/hour
Application limits
Max. gate weight
250 kg (max. 1.5 m)
Max. gate width
2.3 m (max. 200 Kg)
TECHNISCHE DATEN
Versorgungsspannung
230 V - 50 Hz
Motorspannung
24 Vdc
Max. Leistungsaufnahme
150 W
Max. Stromaufnahme
5 A
Max. Drehmoment
180 Nm
Öffnungs- und Schließzeit (95°)
16 s
(15 s mit Gleitschiene )
Schutzart
IP 53
Schmierung
fett
Betriebstemperatur
-20°C +50°C
Gewicht Bart 350 Master
10 Kg
Gewicht Bart 350 Slave
6,5 Kg
Max. zulässige Betriebsfrequenz
30 Zyklen/Stunde
Anwendungsgrenzen
Max. Torgewicht
250 kg (max. 1,5 m)
Max. Torflügel Breite
2,3 m (max. 200 Kg)
TECHNISCHE GEGEVENS
Voedingsspanning
230 V - 50 Hz
Motorspanning
24 Vcc
Verbruikt vermogen max
150 W
Verbruikte stroom max
5 A
Maximaal koppel
180 Nm
Tijd open-dicht (95°)
16 s
(15 s met geleider)
Beschermingsgraad
IP 53
Smering
vet
Bedrijfstemperatuur
-20°C +50°C
Gewicht de Bart 350 Master
10 Kg
Gewicht de Bart 350 Slave
6,5 Kg
Toelaatbare maximum bedrijfsfrequentie 30 cycli/uur
Beperkingen van gebruik
Maximaal gewicht vleugel
250 kg (max. 1,5 m)
Maximunlengte vleugel
2,3 m (max. 200 Kg)
The manufacturing firm reserves the right to modify this manual without notice.
Der Hersteller behält sich vor, ohne Vorankündigung Änderungen an dieser Anleitung
vorzunehmen.
Der Hersteller behält sich vor, ohne Vorankündigung Änderungen an dieser Anleitung
vorzunehmen.
Содержание Bart 350
Страница 9: ...pag 9 Fig 11 Fig 14 Fig 13 Fig 12...