ISO 9001 / ISO 14001 / OHSAS 18001
-
8
-
RP-6016m
transmitter module
1
2
3
4
5
6
1. Channel indicator
2. Antenna socket(TNC type)
3. Channel selectors: Press
▲
(up)
▼
(down) to increase/decrease channel number. Please
select a non-interfering frequency channel to those used in the receiver modules.
4. Power switch
5. Audio sensitivity: Clockwise to increase its sensitivity level and anticlockwise to reduce.
6. Output power setting: LOW (left) for Low output power and HI (right) for high output power.
Low output power will reduce the RF transmission distance and High output power will
extend the possible RF transmission distance. However, if the module is installed on battery-
powered amplifiers, HIGH output power would reduce more operation time than LOW output
power since it requires more power for longer RF transmission.