background image

ISO 9001 / ISO 14001 / OHSAS 18001

 

 

 

-

4

Operating procedures 

After unpacking the unit for the first time, please charge the unit for at least 6 hours before 
operation. This is absolutely necessary as the built-in rechargeable batteries might have been 
discharged naturally due to long shipment and storage time, even though it has been fully 
charged in the factory prior to shipment. 
 
To operate this portable sound unit, switch on the main POWER switch. If the Battery low 
indicator also glows, it means the batteries are weak and please recharge them. 
 
The main POWER switch does NOT switch on the other devices as each of them has individual 
Power/Volume control. To operate each of them, you must switch them on accordingly. 
 

Operating the dynamic wired microphone 

To use a cable microphone, simply plug it into the MIC IN socket. The mic socket accepts both 
phone and Cannon jack. Rotate the dedicated volume control knob and master volume control, 
amplified sound could be heard from the speaker when voice is spoken into the cable 
microphone. 
 

Operating the wireless microphone system 

To operate the wireless system, just switch on the power/volume control on the module panel 
and the matching transmitter. Please have the channel setting on both the transmitter and 
receiver module being the same before operation. Please as well make sure that master 
volume control is set to minimum level before turning the unit on, especially working on a 
wireless version! Set the Master volume control to the mid position. Rotate the volume control 
knob on receiver panel clockwise to the desired levels. When voice is spoken into the 
microphone, amplified sound should be heard over the built-in speaker. 
 

Voice Priority (Ducking) operation 

Voice Priority operation is only necessary when Cassette tape or CD is playing. When the 
Voice Priority switch is put to ON position, the ducking function will be activated. While the 
music is playing, a voice input from either a Wired or Wireless  
Microphone will temporary override and turn down the volume of the background music and 
voice could be heard clearly. 
Background music will return to its original setting when no audio input is entering the 
microphone for a certain time. However, if the microphone is not switch off, the reentering of 
music into the microphone will also activate the voice priority function. So, Voice priority is best 
operated using microphones with on/off switch. 
 

Battery Charging  

Internally, the PRESENTER ONE contains 2 pcs of 12V/5AH maintenance free lead acid 
battery, which has no memory effect. 
When the batteries are weak, the battery low indicator LED will stay RED. To charge the 
batteries, simply plug in the AC power supply, the charging process will start automatically. 
While charging, the charging indicator will flash RED. When batteries are fully charged, the 
charging indicator will stay GREEN. 
 

 

Содержание PRESENTER ONE

Страница 1: ...Modulized Wireless Portable Amplifier System ISO 9001 2008 GREEN PRODUCT Operation manual...

Страница 2: ...on with no module installed Optional accessories 1 Weather proof dust cover 2 Tripod stand 3 Companion powered speaker PRESENTER TWO 4 Wired microphone Remark Manufacturer reserves the rights to chang...

Страница 3: ...D power volume control 4 Tone voulme control BASS 5 Tone voulme control TREBLE 6 Master volume control 7 Mic input Balanced Unbalanced 8 Line input output R L 9 Voice priority 10 Slave output 11 Batte...

Страница 4: ...smitter 1 Audio link input 2 Audio link output 3 Volume control 4 Speaker out switched 5 Speaker out unswitched 6 24 32V DC input 7 Fuse 8 Power status indicator RED 9 Power status indicator GREEN 10...

Страница 5: ...e sure that master volume control is set to minimum level before turning the unit on especially working on a wireless version Set the Master volume control to the mid position Rotate the volume contro...

Страница 6: ...ster and the other PRESENTER ONE as slave To do that just put the MASTER SLAVE selector switch of the second PRESENTER ONE to SLAVE mode For the MASTER unit Audio Link IN jack should NOT be connected...

Страница 7: ...and largely extends the number limit of SLAVEs Application For crowds of 1000 to 2000 e g speeches or forums Configuration One Master several SLAVEs with receiver module built in Application For crow...

Страница 8: ...received CHANNEL scanning It is the automatic scan function key To perform the scan function the transmitter must be switched off Once the key is being pressed the unit will do an auto scan and the ne...

Страница 9: ...o sensitivity Clockwise to increase its sensitivity level and anticlockwise to reduce 6 Output power setting LOW left for Low output power and HI right for high output power Low output power will redu...

Страница 10: ...if it is in the last track In program entry mode Change to the next track file for program select In play mode pause mode program play mode random play mode Single pressed skip the playing track file...

Страница 11: ...OM REPEAT PLAY ALL V EJECT When this key is pushed door is moved out V V PROG Set to programming mode When programming mode stop key is pushed then program is all cleared V MUTE When this key is pushe...

Страница 12: ...wn to have leakage problem of conductive and corrosive liquid So please remove the batteries if they are not to be used for a long period Other settings 1 Channel setting Use UP or DOWN button to go t...

Страница 13: ...vity Level Use UP or DOWN button to go to the SENS SET page Press UP or DOWN button to increase or decrease the Sensitivity Level of the microphone The MAX level is 4 and the MIN level is 1 When a des...

Страница 14: ...es according to the correct polarity after opening the compartment Many batteries are known to have leakage problem of conductive and corrosive liquid So please remove the batteries if they are not to...

Страница 15: ...ne battery position When the desired battery has been selected it will be automatically saved and stored in the memory Remark NiMH battery must be selected when rechargeable battery is being used Neve...

Страница 16: ...ity internal short circuit deformation in appearance erosion of charged ends and decrease in open circuit voltage are symbols indicating battery is approaching the end of its life cycle 6 When two bat...

Отзывы: