You can solve many common air conditioner problems easily, saving you the cost of a service call. Try the suggestions below to 

see whether you can solve your problem without outside help.

Air conditioner will not operate

The power supply cord is unplugged. Plug into grounded 

3 -prong

 outlet. See “Electrical Requirements.”

The power supply cord trips (Reset button will pop out). 
Press and release RESET (listen for click; Reset button will 
latch and on some devices, a green light will turn on) to 
resume operation.

A household fuse has blown or circuit breaker has 
tripped. 
Replace the fuse or reset the circuit breaker. See 
“Electrical Requirements.”

Depending on model, the Power button has not been 
pressed or the Fan Speed control is turned to Off. 
Press 
POWER button or turn the FAN SPEED control to an active 
setting.

The local power has failed. Wait for power to be restored.

Air conditioner blows fuses or trips circuit breakers

Too many appliances are being used on the same circuit. 
Unplug or relocate appliances that share the same circuit.

Time-delay fuse or circuit breaker of the wrong capacity 
is being used. 
Replace with a time-delay fuse or circuit 
breaker of the correct capacity. See “Electrical 
Requirements.”

An extension cord is being used. Do not use an extension 
cord with this or any other appliance.

You are trying to restart the air conditioner too soon after 
turning the unit off. 

Wait for

 at least 3 minutes after turning the 

unit off before trying to restart the air conditioner.

Air conditioner power supply cord trips (Reset button 
pops out)

Disturbances in your electrical current can trip (Reset 
button will pop out) the power supply cord.
 Press and 
release RESET (listen for click; Reset button will latch and on 
some devices, a green light will turn on) to resume operation.

An electrical overloading, overheating, pinching or aging 
can trip (Reset button will pop out) the power supply 
cord.
 After correcting the problem, press and release RESET 
(listen for click; Reset button will latch and on some devices, 
a green light will turn on) to resume operation.

NOTE: A damaged power supply cord must be replaced with a 
new power supply cord obtained from the product manufacturer. 
A damaged power supply cord must not be repaired.

Air conditioner seems to run too much

The current air conditioner replaced an older model. The 
use of more efficient components may cause the air 
conditioner to run longer than an older model, but the total 
energy consumption will be less. Newer air conditioners do 
not emit the “blast” of cold air you may be accustomed to 
from older units, but this is not an indication of lesser cooling 
capacity or efficiency. Refer to the efficiency rating (EER) and 
capacity rating (in BTU/hr.) marked on the air conditioner.

The air conditioner is in a heavily occupied room, or heat-
producing appliances are in use in the room. 
Use exhaust 
vent fans while cooking or bathing and try not to use heat-
producing appliances during the hottest part of the day. A 
higher capacity air conditioner may be required, depending 
on the size of the room being cooled.

Air conditioner cycles on and off too much or does not 
cool

The Mode is set to Power Saver (on some models). Use 
Power Saver only when you are away from home or asleep, 
since the fan does not circulate the room air continuously. 
Use Low, High or Turbo for your best comfort.

The air conditioner is not properly sized for your room. 
Check the cooling capabilities of your room air conditioner. 
Room air conditioners are not designed to cool multiple 
rooms. 

The filter is dirty or obstructed by debris. Clean the filter. 

The inside evaporator and outside condenser coils are 
dirty or obstructed by debris.
 See “Annual Maintenance.”

There is excessive heat or moisture (open container 
cooking, showers, etc.) in the room.
 Use a fan to exhaust 
heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of 

a

 day.

The louvers are blocked. Install the air conditioner in a 
location where the louvers are free from curtains, blinds, 
furniture, etc.

The outside temperature is below 65°F (18°C). Do not try to 
operate your air conditioner in the cooling mode when the 
outside temperature is below 65°F (18°C).

The temperature of the room you are trying to cool is 
extremely hot. 
Allow extra time for the air conditioner to cool 
off a very hot room.

Windows or doors to the outside are open. Close all 
windows and doors.

The Exhaust control is set to OPEN (on some models). 
Push the Exhaust control CLOSED for maximum cooling.

Depending on model, the Temp/Time or Temperature 
control is not at a cool enough setting. 
Adjust the TEMP/
TIME control to a cooler setting by pressing the minus button 
to reduce the temperature or adjust the TEMPERATURE 
control to a cooler setting by turning the knob clockwise. Set 
the FAN SPEED control to highest setting (Turbo or High, 
depending on model).

Water drips from cabinet into your house

The air conditioner is not properly leveled. The air 
conditioner should slope slightly downward toward the 
outside. Level the air conditioner to provide a downward 
slope toward the outside to ensure proper drainage. See the 
Installation Instructions. 

NOTE: Do not drill a hole in the bottom of the metal base and 
condensate pan.

 

Troubleshooting

1

1

Содержание GJC05BJ-A3MND1A

Страница 1: ...15625006 GJC05BJ A3MND1A Model mod le WINDOW AIR CONDITIONER DE FEN TRE CLIMATISEUR Operator s manual p 1 Guide de l utilisateur p 13...

Страница 2: ...1 1 SAFETY PRECAUTIONS 2 2 INSTALLATION INSTRUCTIONS 6 3 AIR CONDITIONER USE 9 4 CARE AND CLEANING 10 6 WARRANTY 12 an an to be used 5 TROUBLESHOOTING 11...

Страница 3: ...grounding grounding A damaged appliance place 2 towards smells...

Страница 4: ...than air cooling 3 Otherwise an or open windows water entering the house Make sure the outdoor installation bracket is not damaged objects The appliance s surfaces may become discoloured or scratched...

Страница 5: ...rt below Follow the requirements for the type of plug on the power supply cord Power supply cord Wiring requirements 115 volt 103 5 min 126 5 max 0 12 amps 15 amp time delay fuse or circuit breaker Us...

Страница 6: ...cs that sense leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply...

Страница 7: ...t during winter or when not in use Some assembly is required Please read these instructions carefully 3 4 screws Drill If pilot holcs are needed When handling unit be careful to avoid cuts from sharp...

Страница 8: ...Place adjust 1 1 2 38 1 mm 1 2 12 7 mm to fit 7...

Страница 9: ...To Remove the Air Conditioner from the Window debris 8...

Страница 10: ...the set temperature is achieved the thermostat will automatically start and stop the compressor 9 space High Low possibly tripping the...

Страница 11: ...the filter with liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure that the filter is thoroughly dry before replacing service 10 Cust...

Страница 12: ...cold air you may be accustomed to from older units but this is not an indication of lesser cooling capacity or efficiency Refer to the efficiency rating EER and capacity rating in BTU hr marked on the...

Страница 13: ...e usage are not guaranteed RONA is not responsible for any costs related to labour injuries or any other loss incurred during the product installation repair or replacement including any indirect or c...

Страница 14: ...s occuper 1 PR CAUTIONS POUR LA S CURIT 14 2 INSTRUCTIONS D INSTALLATION 18 3 UTILISATION DU CLIMATISEUR 21 4 NETTOYAGE ET ENTRETIEN 23 6 GARANTIE 27 13 de l argent tout au long de 5 D PANNAGE 25 les...

Страница 15: ...ir vers les occupants de la pi ce V rifier que l appareil est correctement mis la terre Une mise la terre inad quate peut entra ner un choc lectrique D brancher l appareil s il met des bruits inhabitu...

Страница 16: ...le disjoncteur D brancher le cordon d alimentation et communiquer avec un technicien sp cialis Pr cautions pour la s curit Arr ter l appareil des dommages des dommages des dommages 15 Autrement un D b...

Страница 17: ...adaptateur signal tique Exigences lectriques AVERTISSEMENT Danger d lectrocution Branchez l appareil dans une prise avec mise la Ne retirez pas la broche de terre N utilisez pas de rallonge N utilisez...

Страница 18: ...nt Si le cordon est cras l lectronique d tecte le courant de fuite et l alimentation est d connect e en une fraction de seconde Pour tester votre cordon d alimentation 1 Branchez le cordon dans une pr...

Страница 19: ...lis Un montage est n cessaire Lisez ces instructions attentivement Fixations Qt Vis 3 4 19 mm Verrou de ch ssis 6 1 OUTILLAGE N CESSAIRE Tournevis cruciforme Perceuse Si des avant trous sont n cessair...

Страница 20: ...ce que la planche ou la pi ce de bois soit plus haute d environ 1 2 13 mm que le ch ssis de la contre fen tre Cela permettra au climatiseur d tre suffisamment inclin pour une bonne vacuation Voir la...

Страница 21: ...es ch ssis de la fen tre pour emp cher l air et les d bris d entrer dans la pi ce Voir la FIG 12 Pour retirer le climatiseur de la fen tre 1 Mettez le climatiseur hors tension puis d branchez le cordo...

Страница 22: ...l appareil est utilis en MODE REFROIDISSEMENT Pour r gler la temp rature de pi ce d sir e tournez le commutateur du thermostat au r glage de votre choix Une fois la temp rature r gl e atteinte le ther...

Страница 23: ...ventuel d clenchement de disjoncteur 2 DIRECTIONS ROUE VIS SANS FIN Volets d air directionnels Les volets d air directionnels commandent la direction du d bit d air Votre climatiseur utilise le type...

Страница 24: ...emonter Au lieu de le laver vous pouvez galement nettoyer le filtre l aide d un aspirateur Assurez vous de d brancher le climatiseur afin d viter le risque d lectrocution ou d incendie Le bo tier et l...

Страница 25: ...climatiseur ou coupez l lectricit 2 Nettoyez le panneau avant avec un chiffon doux et humide 3 S chez le panneau avant compl tement 4 Branchez le climatiseur ou r tablissez le courant R paration des...

Страница 26: ...fonctionner le climatiseur plus longtemps qu un mod le plus ancien mais la consommation d nergie totale sera inf rieure Les climatiseurs plus r cents n mettent pas le souffle d air froid des appareils...

Страница 27: ...tres et toutes les portes La commande d chappement est r gl e sur OPEN ouverte certains mod les Poussez la commande d chappement sur CLOSED ferm e pour un refroidissement maximal Selon le mod le la c...

Страница 28: ...FACTO qualit et est garanti pour Garantie 27 66129916667...

Отзывы: