UK/IRL
31
UK/IRL
30
Silva
Spectra
Spectra log burner
Description
Company part
Company part
Company part
Surround silver
20816750
A9264849
A9264849
Door silver
20816650
–
–
Glass
04508000
04506400
04506400
Injector
13382220
13382240
13389170 / 13389160
Burner
20817200
20900184
20900183
Log set
20772900
20773200
20773700
Receiver 20604000
20604000
20604000
Remote control
20603900
20603900
20603900
Transformer
20900142
20900142
20900142
Gas control
37003089
37003089
37003089
Motor (remote control)
37003086
37003086
37003086
Pilot assembly
20900155
20900155
20900145
Thermo couple
37002041
37002041
37002041
Embers
20900019
20900019
20777300
TTB 110°
37006055
37006055
37006055
Black spray for
combustion chamber
09000008
09000008
09000008
Touch Latch assembly
28103900
–
–
INDEX 1 LIST OF SPARE PARTS
UK/IRL
8.1.9 Combustion test
A BS7967 combustion analysis check should be carried out using an
analyser to BS7927 positioned in the flue outlet, or draft diverter.
A Ratio of CO/CO2 should be less than 0.01 within 30 minutes.
(100 ppm CO per 1% CO2).
A reading of CO in the room centre should give a rise of less than
9 ppm over ambient, peak reading.