![Faber SERENE C11 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/faber/serene-c11/serene-c11_installation-manual_3395422012.webp)
11 <
<
<
<
UK
IRL
terminal or roof mounted terminal. To obtain a smoke sealed connection, the inner pipe
must be 20 mm longer then the outside pipe
4.7
Placing the Log set
Never place extra elements of any kind into the combustion chamber. To guarantee good
combustion, the log set may only be installed in the way specified by Faber International.
Any other arrangement can lead to soot on logs or window. Do not use the fire with broken
or missing logs.
On the bottom of the logs on the burners is a identification:
•
1 dimple: first log left placed over the burner and resting on the burner tray.
•
2 dimples: placed in the middle over he burner and resting on the burner tray.
•
3 dimples: the right side log placed over the burner and resting on the burner tray.
L location on the left side resting on the rear log.
R location on the right side resting on the rear log.
See picture 4 how the logs should be positioned. You are allowed to add different kind of
embers on the burner tray to create your own ash bed.
4.8
Placing the glass
Be sure that there are no fingerprints on the glass. hey will be burnt in.
•
Place the glass together with the frame over the screws A (see figures 1.1 and 2.1)
•
Place the screws B (see figures 1.1 and 2.1)
4.9
Placing the Frame (Serene)
•
Place the outer frame over the builders opening (see figure 1.1)
•
Place the screws C (see figure 1.2)
•
Place the smaller inner frame over the outer frame (see figure 1.3)
•
Place the screws D (see figure 1.3)
•
Close the door. The door will be held in position by a snap lock (see figure 1.4)
4.10
Placing the Frame (Emotion / Intense)
•
Align the cavities (see pointer C) with the brackets (see pointer D). Hence in figure
2.2 the backside of the frame is shown!
•
Place the frame with the cavities over the brackets (see pointer D)
•
Let the frame move down (see figure 2.3)
•
Let de frame move towards the appliance till the magnets (see pointer E) click
Содержание SERENE C11
Страница 1: ...SERENE C11 EMOTION C11 INTENSE C11 Installation Guide IRL UK 40010716 0822...
Страница 2: ...1 UK IRL Serene 1 1 1 2 1 3 1 4 1 5 C C C C B B B A A A D D...
Страница 3: ...2 UK IRL Emotion Intense 2 1 2 2 2 3 2 4 D D C C E E A A A B B B...
Страница 19: ...18 UK IRL Appendix D Dimensions Serene...
Страница 20: ...19 UK IRL Appendix E Dimensions Emotion...
Страница 21: ...20 UK IRL Appendix F Dimensions Intense...
Страница 22: ...21 UK IRL Appendix G Dimensions Convection grid...
Страница 23: ...22 UK IRL...