VENTING   REQUIREMENTS

Determine which venting method is best for your applica-
tion.  Ductwork can extend either through the wall or the
roof.

The length of the ductwork and the number of elbows
should be kept to a minimum to provide efficient perfor-
mance.  The size of the ductwork should be uniform.  Do
not install two elbows together.  Use duct tape to seal all
joints in the ductwork system.  Use caulking to seal exterior
wall or floor opening around the cap.

Flexible ductwork is not recommended. Flexible
ductwork creates back pressure and air turbulence
that greatly reduces performance.

Make sure there is proper clearance within the wall or floor
for exhaust duct before making cutouts.  Do not cut a joist
or stud unless absolutely necessary.  If a joist or stud must
be cut, then a supporting frame must be constructed.

FOR MORE SPECIFIC DUCTWORK INFORMATION,

GO TO PAGE 4.

WARNING - To Reduce The Risk Of Fire, Use Only
Metal Ductwork.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on
a separate 15 amp fused circuit.  A time-delay fuse or
circuit breaker is recommended.  The fuse must be sized
per local codes in accordance with the electrical rating of
this unit as specified on the serial/rating plate located
inside the unit near the field wiring compartment.  THIS
UNIT MUST BE CONNECTED WITH COPPER WIRE
ONLY.  Wire sizes must conform to the requirements of the
National Electrical Code, ANSI/NFPA 70 - latest edition,
and all local codes and ordinances.  Wire size and connec-
tions must conform with the rating of the appliance.  Copies
of the standard listed above may be obtained from:

National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts  02269

Version 12/02 - Page 2

• Venting system MUST terminate outside the

home.

• DO NOT terminate the ductwork in an attic or

other enclosed space.

• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
• DO NOT obstruct the flow of combustion and

ventilation air.

• Failure to follow venting requirements may

result in a  fire.

This appliance should be connected directly to the fused
disconnect (or circuit breaker) through flexible, armored or
nonmetallic sheathed copper cable.  Allow some slack in
the cable so the appliance can be moved if servicing is ever
necessary.  A UL Listed, 1/2" conduit connector must be
provided at each end of the power supply cable (at the
appliance and at the junction box).

When making the electrical connection, cut a 1   1/4" hole
in the wall.  A hole cut through wood must be sanded until
smooth.  A hole through metal must have a grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELEC-
TRIC SHOCK, do not use this fan with any solid-state
speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:  Use this unit only in the manner
intended by the manufacturer.  If you have any ques-
tions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only.  Do Not Use
To Exhaust Hazardous  or  Explosive Materials and
Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING: Installation Work And Electrical
Wiring Must Be Done By Qualified Person(s) In Accor-
dance With All Applicable Codes And Standards, In-
cluding Fire-Rated Construction.

Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting.  Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Soci-
ety for Heating, Refrigeration and Air Conditioning Engi-
neers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

   WARNING

!

• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic,

nonmetallic gaskets or other materials, DO NOT
use for grounding.

• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding

circuit.  A fuse in the neutral or grounding circuit
could result in electrical shock.

• Check with a qualified electrician if you are in

doubt as to whether the rangehood is properly
grounded.

• Failure to follow electrical requirements may

result in a fire.

   WARNING

!

Содержание Pro Magnum

Страница 1: ...eusedandtheappliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA TABLE DE CUI...

Страница 2: ...e appliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When making th...

Страница 3: ...cessaire pourtouslesappareils combustion Suivezlesconseils et mesures de s curit du fournisseur tels que ceux publi s par l Association Nationale de la Sauvegarde contre l Incendie et l Association A...

Страница 4: ...gehood could result in damage to the product or personal injury PERSONAL INJURY HAZARD 9 Feet Straight Duct 2 90 Elbows Wall Cap Total System 9 0 feet 10 0 feet 0 0 feet 19 0 feet FIGURE 2 3 0 feet 5...

Страница 5: ...angehood must be turned to the rear The dimensions for the duct openings are given in FIGURE 8 The 48 model uses two 3 1 4 by 10 duct openings Install all ductwork before installing the rangehood 6 De...

Страница 6: ...extend the bracket 6 Install the damper before hanging the rangehood The damper attaches to the rangehood by two small screws provided in the hardware package If 48 hood is to be connected to 10 round...

Страница 7: ...s designed to remove smoke cook ing vapors and odors from the cooktop area Rangehood Control Panel The control panel is located on the right hand side under the canopy The position and function of eac...

Отзывы: