VENTING   REQUIREMENTS

Determine which venting method is best for your application.  

Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should 

be  kept  to  a  minimum  to  provide  efficient  performance.  

The size of the ductwork should be uniform.  Do not install 

two elbows together.  Use duct tape to seal all joints in the 

ductwork system.  Use caulking to seal exterior wall or floor 

opening around the cap.

Flexible ductwork is not recommended.  Flexible ductwork 

creates  back  pressure  and  air  turbulence  that  greatly 

reduces performance.

Make sure there is proper clearance within the wall or floor 

for exhaust duct before making cutouts.  Do not cut a joist 

or stud unless absolutely necessary.  If a joist or stud must 

be cut, then a supporting frame must be constructed

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 

TO PAGE 5.

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

ELECTRICAL REQUIREMENTS

• Venting system MUST terminate outside the 

home.

• DO NOT terminate the ductwork in an attic or 

other enclosed space.

• DO NOT use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.

• DO NOT obstruct the flow of combustion and 

ventilation air.

• Failure to follow venting requirements may result 

in a  fire.

This appliance should be connected directly to the fused 

disconnect  (or  circuit  breaker)  through  flexible,  armored 

or nonmetallic sheathed copper cable.  Allow some slack 

in the cable so the appliance can be moved if servicing is 

ever necessary.  A UL Listed, 1/2" conduit connector must 

be provided at each end of the power supply cable (at the 

appliance and at the junction box).

When making the electrical connection, cut a 1   1/4" hole 

in the wall.  A hole cut through wood must be sanded until 

smooth.  A hole through metal must have a grommet. 

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do 

not use this fan with any solid-state speed control device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:  Use this unit only 

in the manner intended by the manufacturer.  If you have any ques-

tions, contact the manufacturer.

Before servicing or cleaning unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from 

being switched on accidentally.  When the service disconnecting 

means  cannot  be  locked,  securely  fasten  a  prominent  warning 

device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only.  Do Not Use To Exhaust 

Hazardous  or  Explosive Materials and Vapors.

WARNING  -  TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRICAL  SHOCK, 

OR  INJURY  TO  PERSONS,  OBSERVE  THE  FOLLOWING:  Installation 

Work And Electrical Wiring Must Be Done By Qualified Person(s) 

In Accordance With All Applicable Codes And Standards, Including 

Fire-Rated Construction.  

Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

backdrafting.  Follow the heating equipment manufacturer's guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA), and the American Society for Heat-

ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and the 

local code authorities.

When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

   WARNING

• Electrical ground is required on this rangehood.

• If cold water pipe is interrupted by plastic, 

nonmetallic gaskets or other materials, DO NOT 

use for grounding.

• DO NOT ground to a gas pipe.

• DO NOT have a fuse in the neutral or grounding 

circuit.  A fuse in the neutral or grounding circuit 

could result in electrical shock.

• Check with a qualified electrician if you are in 

doubt as to whether the rangehood is properly 

grounded. 

• Failure to follow electrical requirements may result 

in a fire.   

   WARNING

A 120 volt, 60 Hz AC-only electrical supply is required on a 

separate 15 amp fused circuit.  A time-delay fuse or circuit 

breaker is recommended.  The fuse must be sized per local 

codes in accordance with the electrical rating of this unit as 

specified  on  the  serial/rating  plate  located  inside  the  unit 

near the field wiring compartment.  THIS UNIT MUST BE 

CONNECTED WITH COPPER WIRE ONLY.  Wire sizes must 

conform to the requirements of the National Electrical Code, 

ANSI/NFPA 70 - latest edition, and all local codes and ordi-

nances.  Wire size and connections must conform with the 

rating of the appliance.  Copies of the standard listed above 

may be obtained from: 

 

National Fire Protection Association

 

Batterymarch Park

 

Quincy, Massachusetts  02269

For residential use only.

!

!

Содержание Magnum

Страница 1: ...D Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POUR MINIMISER LE RI...

Страница 2: ...d lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a t...

Страница 3: ...esures de s curit du fournisseur tels que ceux publi s par l Association Nationale de la Sauvegarde contre l Incendie et l Association Am ricaine d Ing nieurs de Chauffage Frigorifaction et Air Climat...

Страница 4: ...iterature Package PARTS NEEDED FOR INSTALLATION 2 Conduit Connectors Power Supply Cable 1 Wall or Roof Cap All Metal Ductwork OPTIONAL ACCESSORIES AVAILABLE Charcoal Filter Kit For recirculating insta...

Страница 5: ...quires 6 round ductwork To ensure that the blower performs to its highest possible capacity ductwork should be as short and straight as possilbe WARNING BEFORE MAKING ANY CUTS OR HOLESFORINSTALLATION...

Страница 6: ...strain relief in power supply cable opening so that clamping screws are inside of rangehood 10 Attach damper to exhaust opening on top of the range hood using the two small screws from the hardware pa...

Страница 7: ...lamp the bezel A around the lamp C must be removed as indicated in FIGURE 14 This bezel A is held in place by two screws B Remove the two screws and the bezel Thenremovethelampandreplacewithanewlamp O...

Страница 8: ...documentation PI CES N CESSAIRES POUR L INSTALLATION 2 connecteurs de conduit C ble d alimentation 1 capuchon de mur ou de toit Conduit en m tal ACCESSOIRES POUR L INSTALLATION Filtres au Charbon Pou...

Страница 9: ...0 pi 5 0 pi 12 0 pi 0 0 pi Coude 45 Coude 90 Coude plat 90 Capuchon de mur FIGURE 4 9 pi de conduit droit 2 Coudes 90 Capuchon de mur Syst me total 9 0 pi 10 0 pi 0 0 pi 19 0 pi FIGURE 5 Pour de meil...

Страница 10: ...age 9 ter le couvercle du bo tier de connexion paroi arri re delahotte Avecuntournevis lameplate enleverl opercule arrachable du trou de passaage du c ble Installer le serre c ble sur le trou veiller...

Страница 11: ...ndiqu es la FIGURE 13 Bouton marche arr t de la lumi re L Interrupteur marche arr t pour la lumi re R gler 1 pour mettre en circuit ON ou 0 pour mettre hors circuit OFF Bouton marche arr t du ventilat...

Страница 12: ......

Отзывы: