ALL  WALL  AND  FLOOR  OPENINGS  WHERE  THE  RANGEHOOD  IS  INSTALLED  MUST  

BE  SEALED.

This rangehood requires at least 24" of clearance 

between the bottom of the rangehood 

and the cooking surface or countertop. This hood has been approved by UL at this distance 

from the cooktop. 

This minimum clearance may be higher depending on local building codes. For gas cooktops 

and combination ranges, a minimum of 30" is recommended and may be required.

The maximum depth of overhead cabinets is 13". Overhead cabinets on both sides of this unit 

must be a minimum of 18" above the cooking surface or countertop. Consult the cooktop or 

range installation instructions given by the manufacturer before making any cutouts. 

MOBILE HOME INSTALLATION The installation of this rangehood must conform to the 

Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly 

Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See 

Electrical Requirements.

• Venting system MUST terminate outside the home.

• 

DO NOT

 terminate the ductwork in an attic or other enclosed space.

• 

DO NOT

 use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.

• 

DO NOT

 obstruct the flow of combustion and ventilation air.

• Failure to follow venting requirements may result in a  fire.

   WARNING

!

Cold Weather installations

An additional back draft damper should be installed to minimize backward cold air flow and a 

nonmetallic thermal break should be installed to minimize conduction of outside temperatures as 

part of the vent system. The damper should be on the cold air side of the thermal break. The break 

should be as close as possible to where the vent system enters the heated portion of the house.

VENTING   REQUIREMENTS

Determine which venting method is best for your application.  Ductwork can extend either through the 

wall or the roof.

The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient 

performance.  The size of the ductwork should be uniform.  Do not install two elbows together.  Use 

duct tape to seal all joints in the ductwork system.  Use caulking to seal exterior wall or floor opening 

around the cap.

Flexible ductwork is not recommended.  Flexible ductwork creates back pressure and air turbulence 

that greatly reduces performance.

Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts.  

Do not cut a joist or stud unless absolutely necessary.  If a joist or stud must be cut, then a supporting 

frame must be constructed. 

WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.

CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do 

not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. 

3.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and 

other hidden utilities.

4.  Ducted fans must always be vented to the outdoors.

Содержание MAESTRALE MAES3018SS600-B

Страница 1: ...OSTR30SS400 OSTR36SS400 Installation Instructions Use and Care Information Instructions d installation Utilisez et d entretien OSTRO...

Страница 2: ...with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK do not use this fan with any solid state speed control device WARNING...

Страница 3: ...d be installed to minimize backward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on...

Страница 4: ...or grounding DO NOT ground to a gas pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock Check with a qualified elect...

Страница 5: ...5 RANGEHOOD DIMENSIONS RANGEHOOD DIMENSIONS WITH OPTIONAL FULL CHIMNEY RANGEHOOD DIMENSIONS WITH OPTIONAL TELESCOPIC CHIMNEY 29 15 16 35 3 4 29 15 16 35 3 4 29 15 16 35 3 4...

Страница 6: ...Recirculation Kit DUCTGRT30 36 Recirculation Kit DUCTGRT36 Created by Denomination Lang EN Sheet1 1 Modif by Approved by Approval date Doc status Drawing N NEW_DRAWING_BOX Rev 01 10 1 12a 14 13 11b 6...

Страница 7: ...e lters Turn the knob to the left coun terclockwise to release lter Repeat with other lter Reinstall the lter by placing the back edge in the channel at rear of hood Push lter into place turn the knob...

Страница 8: ...8 Ducted Venting Options Installation Horizontal Vertical 6 6 Rear 6 Ducting Methods...

Страница 9: ...r from the body of the Hood and position it so the transition opening is facing to the rear wall from the back remove and rotate 180 degrees to the left and then flip it back 90 degrees as shown in th...

Страница 10: ...uct work must be installed to exhaust the rangehood back into the kitchen either at the top of the cabinet FIGURE 3A or at the face or side of the soffit FIGURE 3B Install at least 15 of metal duct fi...

Страница 11: ...mounting on the Wall Draw a vertical line on the supporting wall as high as practical at the center of the area in which the hood will be installed Draw a horizontal line at where the bottom edgeofth...

Страница 12: ...and at L distance on the left and right of vertical line The distance L change for all dimension of Hood Insert the two wall plugs in the holes as shown and fix 3 4 E E Hookthehoodbodyontothewallplug...

Страница 13: ...wo remaining screws to anchor the hood in holes If your installation uses the optional duct cover t the cover anges over the brackets If installation uses the telescopic chimney extension t the extens...

Страница 14: ...arked Insert the purchased wall plugs in the holes Using two remaining screws to anchor the hood in holes 1 3 4 12a 13 2 6 x 14 Non Ducted Recirculation Option For Non Ducted Recirculation venting rou...

Страница 15: ...d 19 15 32 B Mounting brackets C Top of hood 2 Install each bracket on the wall as shown Make sure the screws and brackets are securely fastened to the wall IMPORTANT Install only the brackets Do not...

Страница 16: ...re for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING...

Страница 17: ...ff Blower Speed 2 T2 Press this button to turn the hood onto speed 2 indicated by orange LED Blower Speed 3 Intensive T3 Press this button to turn the hood onto speed 3 indicated by solid red LED Hold...

Страница 18: ...ted and must be replaced approximately every 4 months of operation ormorefrequentlyforparticularlyheavyusage Remove the Filters one at a time pushing them towards the back of the unit and at the same...

Страница 19: ...on Creation date 16 Feb 2018 CORRADO DOLCE Created by 991 0349 116 Code 220 240V 50Hz 220 60Hz 110 127V 60Hz F N BLU PNK BRW WHT 1 2 3 4 5 6 BLK Y G 1 2 3 6 5 4 9 8 7 PNK M8 4V BRW ORG M1 V1 MC F V2 E...

Страница 20: ...om accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or Faber documentation or use of products not approved...

Страница 21: ...nevoiedesortiesetrouvederri revouspendantquevous teignezlesflammes D apr sleguide KitchenFiresafetyTips publi parlaNFPAaux tats Unis AVERTISSEMENT POURR DUIRELERISQUED INCENDIEOUDECHOC LECTRIQUE n uti...

Страница 22: ...ences en mati re de ventilation pourrait entra ner un incendie AVERTISSEMENT Installation dans les climats froids Le syst me de ventilation doit pr voir un registre antirefoulement suppl mentaire pour...

Страница 23: ...ILISEZ PAS une conduite de gaz pour la mise la terre N INSTALLEZ PAS un fusible sur le circuit neutre ou le circuit de mise la terre La pr sence d un fusible dans le circuit neutre ou de mise la terre...

Страница 24: ...24 DIMENSIONS DE LA HOTTE DIMENSIONS DE LA HOTTE AVEC CHEMIN E COMPL TE EN OPTION DIMENSIONS DE LA HOTTE AVEC CHEMIN E T LESCOPIQUE EN OPTION 29 15 16 35 3 4 29 15 16 35 3 4 29 15 16 35 3 4...

Страница 25: ...pleine largeur No d article FULL36 Recouvrement de canalisation de chemin e t lescopique TELEMAES R ducteur de d bit accessoire CFMRED2 Filtre charbon actif No d article FILTER1 30 Recirculation Kit D...

Страница 26: ...a gauche sens contraire des aiguilles d une montre pour d gager le filtre R p tez l op ration avec l autre filtre R installez le filtre en pla ant son rebord arri re dans la rainure l arri re de la ho...

Страница 27: ...27 6 6 6 Arri re Horizontale Verticale Options d installation avec ventilation canalis e M thodes de canalisation...

Страница 28: ...la hotte et placez le de fa on ce que l ouverture de passage de l air se trouve face au mur arri re d gagez le de l arri re et faites le tourner de 180 degr s vers la gauche puis inclinez le de 90 de...

Страница 29: ...UCTGRT36 36 2 Une canalisation doit tre install e pour vacuer la hotte dans la cuisine soit au sommet des armoires FIGURE 3A ou sur la face ou le c t du parement FIGURE 3B Installez un conduit m talli...

Страница 30: ...acez une ligne verticale sur le mur d appuileplushautquepossible aucentre del emplacemento lahotteserainstall e Tracez une ligne horizontale l endroit correspondant au bas de la hotte comme repr sent...

Страница 31: ...e et gauche de la ligne verticale La distance L varie en fonction de la dimension de la hotte Ins rez les deux chevilles dans les orifices comme illustr et fixez les 3 4 E E Engagez le b ti de la hott...

Страница 32: ...ancrer la hotte Si votre installation pr voit le recouvrement de canalisation en option placez les flasques du rev tement sur les brides Si l installation pr voit le prolongement de chemin e t lescopi...

Страница 33: ...hevilles achet es dans les trous Ins rez les deux vis restantes dans les trous inf rieurs pour ancrer la hotte au mur 12a 13 6 x 14 Option non canalis e avec recyclage d air Pourlaventilationavecrecyc...

Страница 34: ...e C Haut de la hotte 2 Installez chaque bride sur le mur comme illustr Assurez vous que les vis et brides sont solidement ancr es au mur IMPORTANT Installez les brides uniquement N installez pas la ho...

Страница 35: ...n au courant lectrique Cet appareil est muni d un cordon pr sentant un fil de mise la terre avec une fiche de mise la terre La fiche doit tre ins r e dans une prise correctement install e et mise la t...

Страница 36: ...entilateur 2 T2 Appuyez sur ce bouton pour activer le capot sur la vitesse 2 indiqu par LED orange Vitesse du ventilateur 3 Intensif T3 Appuyez sur ce bouton pour activer la hotte sur la vitesse 3 ind...

Страница 37: ...avable et ne peut pas tre r g n r Il doit tre remplac environ tous les 4 mois d utilisation ou plus souvent en cas d utilisation particuli rement intensive Retirez les filtres un un en les poussant ve...

Страница 38: ...ion Creation date 16 Feb 2018 CORRADO DOLCE Created by 991 0349 116 Code 220 240V 50Hz 220 60Hz 110 127V 60Hz F N BLU PNK BRW WHT 1 2 3 4 5 6 BLK Y G 1 2 3 6 5 4 9 8 7 PNK M8 4V BRW ORG M1 V1 MC F V2...

Страница 39: ...es d coulant d un accident d une modification de l utilisation incorrecte ou abusive d un incendie d une inondation d un cas de force majeure d une installation inad quate d une installation non confo...

Страница 40: ...991 0533 513_02 180221 D0004468_01...

Отзывы: