ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
Chimney Assembly
• Fasten the Chimney fixing element
19
to the Body using 4
screws
12c
.
Upper chimney
• Open the two side pieces out slightly, hook them up behind the
brackets
7.2.1
and bring them back together again until they
are in contact.
• Fix to the Brackets at the sides, using 4 screws
12c
(2.9 x 9.5)
provided.
• If there are any, make sure that the Connector extensions outlet
is in correspondence with the Chimney openings.
Lower chimney
• Open the two side pieces of the Chimney out slightly, hook
them between the upper chimney and the wall, and then close
them together again until they are in contact.
• Fix the part at the sides to the Chimney fixing element
19
, us-
ing 2 screws
12c
(2.9 x 9.5) provided.