EN
9
9
Mounting the hood body
• Before attaching the hood body, tighten the two screws
Vr
lo-
cated on the hood body mounting points.
• Hook the hood body onto the screws
12r
(4,2 x 12,7).
• Fully tighten support screws
12r
(4,2 x 12,7).
• Adjust screws
Vr
to level the hood body.
12r
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
ø 150
9
ø 120
RECIRCULATION VERSION AIR OUTLET
• Push fit connection
15
onto the hood body outlet
.
• Insert the connection extension pieces laterally
14.1
in connec-
tion
15.
• Make sure that the outlet of the extension pieces
14.1
is hori-
zontally and vertically aligned with the chimney outlets. If this
is not the case, adjust the position by either reversing the con-
nection extension pieces
14.1
and then reassemble as described
previously.
• Ensure that the activated charcoal filters have been inserted.
14.1
15
Содержание LI_991.0431.691