NON DUCTED RECIRCULATION OPTION
1
FOR ALL INSTALLATIONS REMOVE ALL WHITE PLASTIC PROTECTIVE COVERING FROM
HOOD, SIDE RAILS, TRIM, GREASE RAILS AND GREASE FILTERS.
IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE
VENTED TO THE OUTSIDE.
For recirculating installations (Figure 1), Charcoal Filters are necessary.
When used in recirculation mode, To Reduce the Risk of Fire and Shock use Charcoal Filters
kit Model #
FILTER1
Remove all grease filters and set aside.
Attach one charcoal filter to each end of the blower. Each charcoal filter attaches to the grid
on the side of the blower. Rotate the filter clockwise to install and counterclockwise to remove
(Figure 1A).
Replace all grease filters. Recirculating installations also require some duct work to divert the air
out of the top or face or side of the cabinet or custom hood or out of the side / face of the soffit and
back into the kitchen. Install at least 15" of vertical run of metal duct (Figure 1) at the air outlet.
Run the duct vertically and secure it at the relevant opening previously cut out at the top or side
of the cabinet or soffit.
A metal duct cover grille is also recommended.
The duct work must not terminate inside the cabinet or custom hood.
FIGURE 1
cabinet
or
custom
hood
ceiling
duct
work
cabinet
or
custom
hood
ceiling
duct
work
Version 07/11 - Page 7
PLAN YOUR DUCTWORK
To ensure that the blower performs to its highest
possible capacity, ductwork should be as short
and straight as possilbe.
The ductrun should not exceed 35 equivalent
feet if ducted using the required minimum of 6"
round duct. For 10" round ducting with the 1200
cfm internal motor or 900 / 1200 remote blower,
use 55 equivalent feet. Calculate the length of
the ductwork by adding the equivalent feet in
FIGURE 5
for each piece of duct in the system
An example is given in
FIGURE 6
.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
as possible.
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
9.0 feet
10.0 feet
0.0 feet
19.0 feet
FIGURE 6
3.0 feet
5.0 feet
12.0 feet
0.0 feet
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 5
FIGURE 4
RECIRCULATING INSTALLATIONS
IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED TO THE OUTSIDE. For recirculating
installations
(FIGURE 4)
,
Charcoal Filters
are necessary. Remove all grease filters and set aside. Attach one charcoal filter to each end
of the blower. Each charcoal filter attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise
to remove
(FIGURE 4A)
. Replace all grease filters. Recirculating installations also require some duct work to divert the air out of the top or
face or side of the cabinet or custom hood or out of the side / face of the soffit and back into the kitchen. Install at least 15" of vertical run of
metal duct
(FIGURE 4)
at the air outlet. Run the duct vertically and secure it at the relevant opening previously cut out at the top or side of
the cabinet or soffit. A metal duct cover grille is also recommended. The duct work must not terminate inside the cabinet or custom hood.
cabinet
or
custom
hood
ceiling
duct
work
duct
work
ceiling
inca pro plus
cabinet
or
custom
hood
MAKE YOUR CUT-OUTS
1.
Disconnect and move freestanding range from cabinet opening to provide easier access
to upper cabinet or custom hood. Put a thick, protective covering over cooktop, set-in range
or countertop to protect from damage or dirt.
2.
Determine and make all necessary cuts in the wall and/or ceiling for the ductwork. Install
the ductwork before the rangehood.
3.
Determine the proper location for the Power Supply Cable. Use a 1
1/4"
Drill Bit to make
this hole. Install the cable. Use caulking to seal around the hole. DO NOT turn on the
power until installation is complete.
4. Choose the knock out hole to remove for installing the power cable. Use a screwdriver
to snap off the knock out covering. (FIGURE 7 shows inside the wiring box and outside)
FIGURE 4A
inca pro plus
FIGURE 7
FOR ALL INSTALLATIONS
REMOVE ALL WHITE PLASTIC PROTECTIVE COVERING FROM HOOD, SIDE RAILS,
TRIM, GREASE RAILS AND GREASE FILTERS
FIGURE 1A
Содержание INCA PRO 18
Страница 6: ...6 RANGE HOOD DIMENSIONS DRAFT 20 JAN 2021 11...
Страница 7: ...7 MIN 24 OVER ELECTRIC MIN 30 OVER GAS INSTALLATION HEIGHT REQUIREMENTS Min 24 Min 30...
Страница 9: ...9 A B C 1 3 6 4 5 2 7 9 10 H I H I 9e 9c 9f D F E G H I L M N O...
Страница 33: ...33 DIMENSIONS DE LA HOTTE DRAFT 20 JAN 2021 11...
Страница 34: ...34 MIN 24 AU DESSUS DE L LECTRICIT MIN 30 SUR GAZ EXIGENCES EN MATI RE DE HAUTEUR D INSTALLATION Min 24 Min 30...
Страница 36: ...36 A B C 1 3 6 4 5 2 7 9 10 H I H I 9e 9c 9f D F E G H I L M N O...
Страница 60: ...60 DIMENSIONES DE LA CAMPANA EXTRACTORA DRAFT 20 JAN 2021 11...
Страница 61: ...61 M N 24 SOBRE EL CTRICO M N 30 SOBRE GAS REQUISITOS DE ALTURA PARA LA INSTALACI N M n 24 M n 30...
Страница 63: ...63 A B C 1 3 6 4 5 2 7 9 10 H I H I 9e 9c 9f D F E G H I L M N O...
Страница 83: ...83...
Страница 84: ...991 0681 695_01 220801 D00008851_00...