10
3
Direct Connect Wiring Box
Accessory sku # WIREBOX
(purchased separately)
Created by
-
Denomination
-
Lang
EN
Sheet
1/1
Modif.by
Approved by
Approval date
Doc. status
Drawing N.
NEW_DRAWING_BOX
Rev
01
ELECTRICAL INSTALLATION WITH CONNECTION CABLE
ELECTRICAL INSTALLATION WITH
OPTIONAL WIRING BOX
For Permanent wiring Installation-Use only
with Listed rangehood Wiring Box kit
sku # WIREBOX, manufactured by Faber.
Max. 33
7/16
”
GROUNDING INSTRUCTIONS This appliance must
be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing
an escape wire for the electric current. This appliance
is equipped with a cord having a grounding wire with a
grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded.
WARNING - Improper grounding can result in a risk of
electric shock.
Consult a qualified electrician if the grounding instructions
are not completely understood, or if doubt exists as to
whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord
is too short, have a qualified electrician install an outlet
near the appliance.
1
2
H
I
4
For Non-Ducted Recirculation Option
Attach each charcoal filter to the black
grid on each side of the blower. Press the
charcoal filter tightly to the black grid on the
blower side and rotate the filter clockwise
(towards the front of the insert hood) until
it locks into place. Turn counterclockwise
(towards the back of the insert hood) to
remove.
Required Activated Charcoal Filter
Accessory - sku # - FILTER1
(purchased separately)
Содержание INCA LUX INLX21SS600-B
Страница 5: ...5 RANGEHOOD DIMENSIONS Min 24 Min 30 47 ...
Страница 14: ...14 Wiring Diagram 991 0350 534 H90 254 r1 ...
Страница 19: ...19 47 DIMENSIONS DE LA HOTTE Min 24 Min 30 ...
Страница 28: ...28 Schéma de câblage 991 0350 534 H90 254 r1 ...
Страница 30: ......
Страница 31: ......
Страница 32: ...991 0381 570_07 181116 D00001420_06 ...