Installation requirements 

Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of 

importance that you do not use the appliance shortly after a renovation of the home. 

Because of the natural circulation of air, moist and volatile components from paint, 

building materials, carpet etc. will be attracted. These components can settle onto cold 

surfaces in the form of soot.  

As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed 

too near to the appliance may become scorched or discoloured. This should be born in 

mind when installing the appliance. 

3.1

 

Builders opening 

The appliance can be installed in a new made hollow wall construction only. For the 

dimensions of the appliance, see appendix F. 

In both cases keep the following in mind: 

 

do not place the appliance on combustible materials or carpets 

 

both walls have to be made of non-combustible material (e.g. Promatect) 

 

do not place the lintel, surround or marble stone directly onto the appliance. If 

possible, apply a lintel made of cement or something similar 

 

always ventilate the space above the appliance. Use a Faber ventilation grid 

 

to avoid cracking, the plaster has to dry for at least 1 day per millimetre plaster 

 

to avoid discolouring the plaster has to be heat resistant to min. 100 °C 

3.2

 

Flue requirements 

 

The appliance is of the type C11/C31. The appliance will need to be supplied with 

the approved flue pipes and terminal, it is not possible to supply your own 

 

a horizontal extension with elbows is allowed for a maximum of 6 meters 

(depending on the situation) 

 

Vertical flue routing between 0.5 – 12 meter (depending on situation) 

Determine on the base of the example calculations in Appendix A and on the base of the 

table in Appendix B if the desired situation is possible. To establish this you will need to 

calculate: 

 

The effective height (this is the real difference in height between the upper side of 

the appliance and the terminal) 

 

The total horizontal extension. This is the total horizontal flue length where: 

1.

 

each elbow, which is in the horizontal area, counts for 2 meters 

2.

 

each 90-degree bend, which is in the horizontal area, counts for 2 meter 

3.

 

each 45-degree bend, which is in the horizontal area, counts for 1 meter 

Содержание Honest

Страница 1: ...Honest Installationguide Sity Gas 40010739 0902 ...

Страница 2: ...1 L L General 1 1 1 2 1 3 1 4 1 5 1 6 Rough adjustment Fine adjustment Bolt Nut Keep at least 10 mm between ...

Страница 3: ... 2 Placing the log set 2 1 2 2 2 3 2 4 ...

Страница 4: ...3 L L Placing the glass 3 1 3 2 3 3 3 4 3 5 3 6 ...

Страница 5: ... Placing the log set 10 4 6 Placing the glass 10 5 Commissioning functional checks 11 5 1 Pilot ignition check 11 5 2 Check functional burner and pilot burner 11 6 Handing over final check and customer briefing 12 7 Servicing 12 7 1 Routine annual servicing 12 Appendix A Example calculation 14 Appendix B Flue restrictor 15 Appendix C Installation of the flue 16 Appendix E Technical specifications ...

Страница 6: ...pattern by use of the patented Log burner technology Room sealed appliance inlet and outlet are led to the outside using a natural draught concentric pipe system 100 mm 150 mm no power fan required Air supply and flue gases go to outside atmosphere through wall or roof Remote Control standard Meets the requirements of the European Gas Appliance Directive GAD and carries the CE mark ...

Страница 7: ...pliance if it has a broken glass General safety It is the law in Denmark that all gas appliances are installed by a competent person in accordance with the Gas Safety Installation and Use Regulations as amended the relevant Denmark Standards for Installation work Building Regulations Codes of Practice and the manufacturers instructions Always use an additional guard if there are elderly infirm or ...

Страница 8: ...ble apply a lintel made of cement or something similar always ventilate the space above the appliance Use a Faber ventilation grid to avoid cracking the plaster has to dry for at least 1 day per millimetre plaster to avoid discolouring the plaster has to be heat resistant to min 100 C 3 2 Flue requirements The appliance is of the type C11 C31 The appliance will need to be supplied with the approve...

Страница 9: ...he manufacturer including wherever possible a dimensioned sketch Avoid locating the terminal in close proximity to plastic materials such as gutters or other combustibles If this is unavoidable then a suitable deflector should be made Some important requirements for a good functioning the wall mounted terminal has to be at least 0 5 m off o Corners of the building o Below eaves o Balcony s etc o T...

Страница 10: ...o adjust the height see fig 1 1 Rough adjustment by removing the nut and bolt Shift the leg 30mm and replace the nut and bolt Fine adjustment by adjusting the couple legs Finally check the explosion lids by visual inspection for closing correctly the lid covers the hole and is level 4 3 Placing the appliance Always keep minimal 10mm distance between the appliance and the surround to apply a ventil...

Страница 11: ...4 As desired the bottom of the appliance can be spread over with embers Never spread the embers over the grid and along the backside 4 6 Placing the glass Note Use both suction lifters to remove place the glass Place the suction lifters on the glass see figure 3 1 Keep the glass tilted backwards for the appliance see figure 3 2 Move the glass carefully downwards between the appliance and the surro...

Страница 12: ...pressure Perform this measuring when the appliance burns on full capacity and when only the pilot ignition burns When the pressure is too low check if the gas pipes are made of material with the right diameter When the pressure is too high more than 5 mBar overpressure you may not install the appliance and you should contact your gas company Always check the burner pressure when the functional pre...

Страница 13: ...the gas supply before commencing any servicing Always test for gas soundness after refitting the appliance 7 1 Routine annual servicing Clean if necessary a the pilot system b the burner c the combustion chamber d the glass Check the log lay and replace the embers if applicable Do the functional test as described in chapter 6 Check the flue system and terminal on damage and soundness visual inspec...

Страница 14: ...ing the combustion chamber and burner If the burner is visibly damaged this can affect the distribution of the flame if so then replace the burner Burner tray assembly Remove the front glass and log holder if applicable Break the gas supply at the control valve Unscrew the burner assembly and take them out of the combustion chamber 7 1 3 Rebuild to other gas category e g Propane butane Rebuilding ...

Страница 15: ...nted terminal 1 m Total effective height 2 m According to the table in Appendix B is this situation allowed without a flue restrictor Please remove the flue restrictor Calculation 2 Calculation horizontal extension fig 2b Flue length J L 0 5 0 5 1 m Elbows K M 2m 2m 4 m Terminal 1 m Total horizontal extension 6 m Calculation effective height Hvert Flue length H 1 m According to the table in Append...

Страница 16: ...he values are outside the table the combination is not allowed Normally the 30 mm flue restrictor is preinstalled Horizontal length m Honest 0 1 2 3 4 5 6 0 X X X X X X X 0 5 X 0 X X X X X 1 30 30 0 0 0 0 X 1 5 30 30 30 0 0 0 0 2 40 40 30 30 0 0 0 3 40 40 40 30 30 0 0 4 50 40 40 40 30 30 0 5 50 40 40 30 30 30 0 6 50 50 40 40 30 30 0 7 60 50 50 40 40 40 X 8 60 50 50 40 40 X X 9 65 60 50 50 X X X 10...

Страница 17: ... so the weight of the pipes is not resting onto the appliance The outside of the pipe can become hot 140 degrees Stay 50 mm away from wall surface or sealing Make sure to provide sufficiently heat resistant isolation when going through the wall or roof Because of expansion or cooling down the concentric pipes can turn loose It is recommended to fix the spring clip cut down pipe with a self tapping...

Страница 18: ... 2 Inlet pressure mbar 8 Gasrate l h 1080 Bij 15º C en 1013 mbar gram h Working pressure high mbar 8 Injector size mm 3x 4mm Reduced input restr mm 2 5 mm Pilot assembly SIT 160 Pilot injector 1 1 mm Drilled Flue system MV Balanced flue Flue size Mm 150 100mm Std Flue restrictor Mm 30mm Gascontrol GV 60 GV60 Connection 3 8 inner Adaptor V 6 Remote Battery V 9 ...

Страница 19: ... 18 Appendix F Dimensions ...

Страница 20: ...19 L L Appendix G Ventilation Grid ...

Страница 21: ... 20 Appendix H Service Hatch ...

Страница 22: ......

Страница 23: ... 2 ...

Страница 24: ...www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen T 31 0 513 656500 F 31 0 513 656501 ...

Отзывы: