27
IMPORTANT: ONLY FOR EXTERNAL BLOWER INSTALLATION
13
WIRING BOX 2 CONNECTION
(
Remote Blower Wiring Box
)
• Connect the cable from the Remote Blower with the two wires inside the Wiring Box 2 by twist-on type
wire connector and matching the color:
- Black with Black
- White with White
• Connect the green ground wire from remote blower to green ground screw.
•
Replace the field wiring compartment cover.
• Check the Wiring Diagram.
A. Remote Blower power supply cable.
B. Black wires.
C. UL listed wire connectors.
D. White wires.
E. Internal Hood Cable.
F. Green ground screw.
1
2
A
E
D
C
B
F
Содержание HIGH-LIGHT Series
Страница 2: ...2...
Страница 96: ...991 0592 992_02 200120 D00006323_01...