3.1 Installation Instruction

3.2 Power Cord Installation

 

Check the capacity of power circuit;

 

Power cord installation;

 

Water heater installation;

 

Plumbing connection;

 

Power supply connection;




 

Water Supply.

Step 1

Step 2

3. UNIT INSTALLATION

Step 3

Step 4

Step 5

Step 6

Remove the screws at the bottom of the unit. Lift 

up the Main Switch Knob and Power Knob  to 

make it free. Remove the front plate gently.

Gash the middle of the film of the power cord 

jacket with a sharp knife in order to put into 

power lines.

Tighten the wire-pressing plate with screws to 

primary position, ensure that the power cord not 

be pulled out more than 60N.

Remove the power cord wire pressing plate and 

keep the screws.

Screw the power cord into the jacket for 

installation of wire pressing plate.

Connect the power cord to wiring terminals; the 

method is as shown in picture.

WARNING

Minimum conductor sizes

Live: 4mm²    Neutral: 4mm²    PE: 4mm² 

!

Содержание FWH SPLASH 301CH

Страница 1: ...struction Manual For Model Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference FWH...

Страница 2: ...e 11 6 Troubleshooting 12 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electric...

Страница 3: ...lacement should be done by a qualified technician or engineer or professionals of the similar products In order to avoid a hazard due to inadvertent resetting of the Earth Leakage Circuit Breaker ELCB...

Страница 4: ...ated Power Rated Current Dia Of Wire Core Air Switch Rated Pressure Minimum Flow Rate Minimum Pressure Maximum Pressure Protection Class Water Proof Class Products Size Knob Quantity 3800W 16A 4mm 20A...

Страница 5: ...r Marker for wateroutlet Water outlet Red Blue PRODUCT STRUCTURE FOR OTTIMO SERIES PRODUCT STRUCTURE FOR SPLASH SERIES Indicator light board Terminal block Silicon control Flow sensor Marker for water...

Страница 6: ...oard Terminal Block Key Board Silicon Control Flow Sensor N PE L G T1 T2 8 5 6 4 7 9 1 2 Silicon Control Temperature Sensor Water Outlet Heating Elements Thermal Cut Out Indicator Light Board Main Con...

Страница 7: ...to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire pressing plate with screws to p...

Страница 8: ...Drive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cov...

Страница 9: ...r must be used when install the unit Blue marker stands for water inlet red marker stands for water outlet Do not overexert to avoid damaging the water heater NOTE A private power cord should be used...

Страница 10: ...ling flicker no heating it can only be used after the failure is excluded When electricity leakage is tested red and green indicator lights are all off stop heating and close the pump system 4 5 To Ad...

Страница 11: ...uthorized service personnel for repair 1 Rotate TEMP knob 2 Repair or replacement the PCB 1 Press the reset handle of the thermal cut out after checking and troubleshooting 2 Change the heating elemen...

Страница 12: ......

Отзывы: