background image

9

4.1 Operating Of The Unit

4.2 Leakage Testing

4.3 To Adjust Water Flow

Switch on the power supply, the unit will take self-inspection for 2s, “ELCB”;  

With

Pump

Bottom Left

"EARTH" blue indicator light will be on (well connected to the Ground). Green 

indicator light will be on (under the condition of no electricity leakage). When  

the water flow exceeds 1.2L/min,  rotate the knob clockwise to switch on heating 

power rotate switch, heating indicator light will be on, the unit start to work. 

4. METHODS OF USING

 

When the water heater is working normally (including working state of PUMP), 

press “TEST” button, if the leakage test circuit is no problem, “ELCB” green 

indicator light will be blinking, and the unit will not heat. Press “RESET”, testing  

will be canceled, and “ELCB” green indicator light will be on, the unit will be back 

to working state set before. If the circuit leaks, press “RESET” button can’t 

cancel  leakage testing, “ELCB”  indicator  light  is twinkling flicker, it means the  

water heater has problems and can’t be used; all the buttons are invalid, heating    

stopped, and pump will be closed.  If "EARTH" blue indicator light is off, is  

it means the heater cannot be connected to the Ground firmly. Please check the  

Grounding before usage.

Rotate the handle of water flow adjusting valve to adjust the water flow.

4.4 Electricity Leakage Protection

When the electricity leakage testing circuit is working normally, if the leakage current is bigger than 

certain value between 7.5mA and 15mA, “EARTH”

“ELCB” and “POWER” indicator light will be 

twinkling  flicker,  no  heating;  it  can  only  be  used  after  the  failure  is  excluded.  (When  electricity 

leakage  is  tested,  red  and  green  indicator  lights  are  all  off,  stop  heating  and  close  the  pump 

system.)

4.5 To Adjust Water Temperature

Rotate the handle of water flow adjusting valve to adjust to proper water flow. Adjust power by rotating 

knob, clockwise rotate, power will be increased and water temperature increase accordingly or vice 

versa.

NOTE

For first time using, ensure electrify after the unit is filled fully with water and there is 

stable water flow comes out from shower head.

The  electric  water  heater  may  be  damaged  if  the  water  hardness  is  too  high.  To 

guarantee the normal service life, please install and put it into use on condition that the 

local water hardness is less than 450mg/L (CaCO3).

If the water flow is small and power is high while using the unit, outlet water temperature is rather 

high; the unit will stop heating automatically. At this time, please lower the power and adjust the

 

water flow faster in order to avoid inconsistency of water temperature.

4.7 Use After Overheating Protection

When the unit is working under normal condition, press “PUMP”, The pump will start immediately and 

while press again, the pump stops.

4.6 To Activate Pump Function (For SPLASH series)

Without

Pump

4.8 "EARTH" LED Indicator (Ground) after power on.

"EARTH" LED ON & "ELCB" ON

a) Water Heater and ground was well connected. Ground was in good condition.

"EARTH" LED OFF & "ELCB" ON

a) Water Heater detect no ground connected or ground was not in good condition.

b) However, water heater still can operate normal with his own performance. 

c) Advice to check ground condition and repair ground if necessary so that water heater are idealy grounded. 

Содержание FWH SPLASH 301CH

Страница 1: ...struction Manual For Model Thank you very much for purchasing our water heater Before installing and operating your water heater please read this manual carefully and keep it for future reference FWH...

Страница 2: ...e 11 6 Troubleshooting 12 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electric...

Страница 3: ...lacement should be done by a qualified technician or engineer or professionals of the similar products In order to avoid a hazard due to inadvertent resetting of the Earth Leakage Circuit Breaker ELCB...

Страница 4: ...ated Power Rated Current Dia Of Wire Core Air Switch Rated Pressure Minimum Flow Rate Minimum Pressure Maximum Pressure Protection Class Water Proof Class Products Size Knob Quantity 3800W 16A 4mm 20A...

Страница 5: ...r Marker for wateroutlet Water outlet Red Blue PRODUCT STRUCTURE FOR OTTIMO SERIES PRODUCT STRUCTURE FOR SPLASH SERIES Indicator light board Terminal block Silicon control Flow sensor Marker for water...

Страница 6: ...oard Terminal Block Key Board Silicon Control Flow Sensor N PE L G T1 T2 8 5 6 4 7 9 1 2 Silicon Control Temperature Sensor Water Outlet Heating Elements Thermal Cut Out Indicator Light Board Main Con...

Страница 7: ...to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire pressing plate with screws to p...

Страница 8: ...Drive in the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cov...

Страница 9: ...r must be used when install the unit Blue marker stands for water inlet red marker stands for water outlet Do not overexert to avoid damaging the water heater NOTE A private power cord should be used...

Страница 10: ...ling flicker no heating it can only be used after the failure is excluded When electricity leakage is tested red and green indicator lights are all off stop heating and close the pump system 4 5 To Ad...

Страница 11: ...uthorized service personnel for repair 1 Rotate TEMP knob 2 Repair or replacement the PCB 1 Press the reset handle of the thermal cut out after checking and troubleshooting 2 Change the heating elemen...

Страница 12: ......

Отзывы: