3) Installation Notes
Before installation, it is very important and needed to read and understand the stated safety
notes, instructions and related information in this manual. This is to ensure the appliance
could be installed appropriately and the user would use it in a proper method in order to avoid
any unnecessary injury and damages. To avoid the risk of fumes suffocation, the cooker hood
should be installed according to the stated instructions and notes in this manual. Next, the
range hood has to install in accordance to the local building guides and regulations therefore
please seek approval from the building management or inspector if necessary before
installation.
4) Venting requirements
1. Do not vent the cooking fumes and air into attic, ceiling and any enclosed area.
2. Make sure the ducting is clean inside for efficient ventilation.
3. The recommended distance between the top surface of cooking hob and the bottom part of
the cooker hood is only between 20 inches to 25 inches (can be adjusted according to
different cooking way).
4. Make sure the mounting height is appropriate as the range hood could be badly damage
and in fire hazard if the range hood mounted too low. If the range hood mounted too high, its
performance and efficiency will be decreased.
5. Both the size of the ducting and the size of air chamber outlet should be consistent.
6. Do not make the ducting turns 90
o
C more than 2 times as each turn will reduce the airflow
efficiency.
7. Make sure the ducting has a length of at least of 24 inches (61cm) before a 90
o
C turn and
between 2 different 90
o
C turn in the same ducting. This is to allow the drawn in fumes and air
have enough room to push through the ducting smoothly.
8. Minimize the length of the adopted ducting and the 90
o
C bents so the range hood could
work at its best. Always make sure the total ducting does not go beyond
9. Please ensure the vent system is completely sealed, if not please use the silver tape or duct
tape to seal it to ensure proper ventilation.
10. Use silicon, plaster and etc. to seal the exterior wall opening or roof opening around the
cap.
11. If turns are needed in the installation, please make sure make it as far as possible from the
air chamber outlet.
12. If the ducting is directed into a central vent flue of a building or house, the ducting outlet
must be adjusted to the flow direction of the vent flue.