Check the connection by pulling the pipe. Secure
the connection with the supplied red / or blue
safety clips.
Please note!
A watertight connection is only guaranteed
with safety clips.
Disassemble the flexible water pipe
Remove the red or blue safety clip.
Push the water pipe in the coupling, hold the
flange in its position and pull the water pipe out of
the coupling.
This appliance is equipped with the following
(overflow) protections:
Electromechanical valve in the control box
that is controlled by sensors in the water
tank.
Absorption valve in the Engine that kicks
in when the water sump has an unexpect-
edly overflow, see fig. 5.0-K.
4.5
LED lighting (optional)
LED bottom lighting
The bottom lighting, which is located in the bottom
plate, can be switched on and off with both the re-
mote control and the App. (See user manual). See
fig. 3.0-FF and 4.0 for the position of the connec-
tion of the led bottom lighting.
LED top lighting
The top lighting can be switched on and off with
both the remote control and the app. (See user
manual). See fig. 3.0-EE and 4.0 for the position of
the connection of the top lighting.
Removing the bottom plate with LED lighting
Please note!
To prevent damage / scratches, it is strongly
recommended to protect the cover strip, see
fig. 4.0-A. Should scratches nevertheless oc-
cur, this can only be repaired with spray paint
(Order number: 09000026).
Remove the decoration set;
Lift the bottom plate in the middle and let
it rest carefully at the front of the fire. See
fig. 4.0.
Loosen the plug connection, for this press
the retaining clip of the plug. Now remove
the bottom plate.
Install LED bottom lighting
Lift the bottom plate in the middle and let
it rest carefully at the front of the fire. See
fig. 4.0.
Insert the plug into the correct connector
of the terminal block (see fig. 3.0-FF and
4.0) and carefully place the bottom plate.
(Check that the cable will not block the
outflow opening (fire opening) of the En-
gine).
4.6
Test mode
Do a performance test (see chapter 7) and check
all water connections for leaks, before installing
the decoration set and the front glass.
Functional test via the ITC-V2 app
(Only possible in dealer setting).
Make sure the ITC-V2 app is connected to the fire.
Navigate to Menu -> Diagnostics / Test mode and
push “Activate”, see fig. 6.0 to 6.3.
The engine can be tested for function.
All components are also checked by a self-test in
the normal starting procedure.
Any error messages are displayed in the App.
Click on the "exclamation mark" symbol at the top
left of the screen for additional information about
the notification.
4.7
Built-in structure and ventilation
requirements
The construction may not rest on the fire.
Take into account the thickness of any fin-
ishing layer!
Keep a minimum distance of 10mm be-
tween built-in frame and false chimney
breast when using combustible material,
see fig. 1.4.
Take into account a minimum distance of
2mm due to expansion of the fireplace,
see fig. 1.4.
Ventilation
The e-MatriX needs a minimum free space
of 50mm above the fire.
The e-MatriX needs a minimum ventila-
tion of 210cm² underneath the fire.
Содержание e-MatriX mood 800/500 I
Страница 1: ...Installation manual e MatriX mood 800 500 I II III e MatriX mood 800 650 I II III ENG 40012136 2202 ...
Страница 2: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 2 ...
Страница 5: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 5 3 0 4 0 EE FF ...
Страница 19: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 19 10 5 Control box ...
Страница 23: ...Installation manual e MatriX mood 800 500 I II III and e MatriX mood 800 650I II III 23 ...
Страница 24: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...