Installation manual e-MatriX heat 800/500 RD,ST (LL)
29 <
<
<
<
4.2
Placing the fire
Please note!
Always the fire must be fitted with back to
a wall.
The fitting of a chimney breast is manda-
tory.
For a proper functioning of the fire, al-
ways ensure that the fire is levelled.
Floor standing
Place the fire in the correct position and fix it to
the wall, see fig. 1.1a or fig. 1.1b.
4.3
Installation and finishing
e-MatriX-RD (fig. 1.0)
With cover strip “A”
Build the false chimney or plateau against dis-
tance holder B.
Without cover strip “A”
Remove distance holder “B” around. Build the
false chimney or plateau against the appliance.
e-MatriX-ST (fig. 1.2)
With cover strip “A”
Build the false chimney or plateau against the
appliance.
Without cover strip “B”
Remove the cover strips “A”, see fig.
1.2.
Build the false chimney or plateau
against the appliance.
4.4
Control box (see fig. 4.0)
Please note!
Fix the Control box at an accessible location
behind the service door, see dimensional
drawing 12.3 and 12.4.
Electric connection
Use the supplied extension cable to con-
nect the Control box to the Engine, see
fig. 4.0-B.
Direct the DC cable, inside the Engine, to
the Control box and connect it,
see fig. 4.0-A:
o
Max. cable length from the cen-
ter of the fire to the left is 1,5m.
o
Max. cable length from the cen-
ter of the fire to the right is 1,0m.
Connect the supplied mains lead,
see fig. 4.0-C.
If desired, an extension set of 2m is available!
(The existing cable length will be extended by 2m,
item number 20901478).
Water connection
This appliance is equipped with the following
(overflow) protections:
-
Electromechanical valve in the Control
box that is controlled by sensors in the
water tank.
-
Absorption valve in the Engine that kicks
in when the water sump has an unexpect-
edly overflow, see fig. 5.0-K.
Connect all parts according flow diagram,
see fig. 5.0.
Place the water filters at an accessible lo-
cation in correct alignment, there’s a
“flow” direction marking on both filters.
Please note!
Carry out a performance test, see chapter 8
and check all connections for water leakage
before placing the fuel bed and front glass.
4.5
Built-in structure
The construction may not rest on the fire.
Keep a minimum distance of 10mm be-
tween built-in frame and false chimney
breast when using combustible material,
see fig. 1.3.
Take into account a minimum distance of
2mm due to expansion of the fireplace,
see fig. 1.3.
Take into account the thickness of any fin-
ishing layer!
Ventilation
The e-MatriX needs a minimum free space
of 50mm above the fire.
The e-MatriX needs a minimum ventila-
tion of 210cm² underneath the fire.
5
Removing glass
5.1
Front glasses e-MatriX-RD
Front glass (see fig. 1.1a, provide service from this
side).
Rotate both glass clamps clockwise.
See fig. 2.0a and 2.0b.
Place the suction cups and remove the
front glass. See fig. 2.0c.
Содержание e-MatriX heat 800/500 RD
Страница 3: ...Installatievoorschrift e MatriX heat 800 500 RD LL e MatriX heat 800 500 ST LL NL ...
Страница 4: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 3 1 0 1 1a 1 1b 1 2 1 3 ...
Страница 5: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 4 2 0a 2 0b 2 0c 2 1 2 2a 2 2b 2 3a 2 3b ...
Страница 6: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 5 2 3c 2 3d 2 3e 2 3f 2 4a 2 4b 2 4c 2 4d 2 4e ...
Страница 7: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 6 3 0a 3 0b 3 1a 3 1b 3 1c 4 0 ...
Страница 9: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 8 6 0 6 1 ...
Страница 10: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 9 7 0 7 1 7 2 7 3 7 4 7 5 7 6 8 0 ...
Страница 17: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 16 12 Maattekeningen 12 1 e MatriX heat 800 500 RD LL ...
Страница 18: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 17 12 2 e MatriX heat 800 500 ST LL ...
Страница 19: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 18 12 3 Control box ...
Страница 20: ...Installatievoorschrift e MatriX heat 800 500 RD ST LL 19 12 4 Bedieningsluikje artikelnummer A9299463 ...
Страница 21: ...Installation manual e MatriX heat 800 500 RD LL e MatriX heat 800 500 ST LL ENG ...
Страница 22: ...Installation manual e MatriX heat 800 500 RD ST LL 21 1 0 1 1a 1 1b 1 2 1 3 ...
Страница 23: ...Installation manual e MatriX heat 800 500 RD ST LL 22 2 0a 2 0b 2 0c 2 1 2 2a 2 2b 2 3a 2 3b ...
Страница 24: ...Installation manual e MatriX heat 800 500 RD ST LL 23 2 3c 2 3d 2 3e 2 3f 2 4a 2 4b 2 4c 2 4d 2 4e ...
Страница 25: ...Installation manual e MatriX heat 800 500 RD ST LL 24 3 0a 3 0b 3 1a 3 1b 3 1c 4 0 ...
Страница 27: ...Installation manual e MatriX heat 800 500 RD ST LL 26 6 0 6 1 ...
Страница 28: ...Installation manual e MatriX heat 800 500 RD ST LL 27 7 0 7 1 7 2 7 3 7 4 7 5 7 6 8 0 ...
Страница 35: ...Installation manual e MatriX heat 800 500 RD ST LL 34 12 Dimensional drawings 12 1 e MatriX heat 800 500 RD LL ...
Страница 36: ...Installation manual e MatriX heat 800 500 RD ST LL 35 12 2 e MatriX heat 800 500 ST LL ...
Страница 37: ...Installation manual e MatriX heat 800 500 RD ST LL 36 12 3 Control box ...
Страница 38: ...Installation manual e MatriX heat 800 500 RD ST LL 37 12 4 Remote access door article number A9299463 ...
Страница 39: ...Installationshandbuch e MatriX heat 800 500 RD LL e MatriX heat 800 500 ST LL DE ...
Страница 40: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 39 1 0 1 1a 1 1b 1 2 1 3 ...
Страница 41: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 40 2 0a 2 0b 2 0c 2 1 2 2a 2 2b 2 3a 2 3b ...
Страница 42: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 41 2 3c 2 3d 2 3e 2 3f 2 4a 2 4b 2 4c 2 4d 2 4e ...
Страница 43: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 42 3 0a 3 0b 3 1a 3 1b 3 1c 4 0 ...
Страница 45: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 44 6 0 6 1 ...
Страница 46: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 45 7 0 7 1 7 2 7 3 7 4 7 5 7 6 8 0 ...
Страница 53: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 52 12 Maßzeichnungen 12 1 e MatriX heat 800 500 RD LL ...
Страница 54: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 53 12 2 e MatriX 800 500 ST LL heat ...
Страница 55: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 54 12 3 Kontrollkasten ...
Страница 56: ...Installationshandbuch e MatriX heat 800 500 RD ST LL 55 12 4 Fernzugriffstür Artikelnummer A9299463 ...
Страница 57: ...Manuel d installation e MatriX heat 800 500 RD LL e MatriX heat 800 500 ST LL FR ...
Страница 58: ...Manuel d installation e MatriX heat 800 500 RD ST LL 57 1 0 1 1a 1 1b 1 2 1 3 ...
Страница 59: ...Manuel d installation e MatriX heat 800 500 RD ST LL 58 2 0a 2 0b 2 0c 2 1 2 2a 2 2b 2 3a 2 3b ...
Страница 60: ...Manuel d installation e MatriX heat 800 500 RD ST LL 59 2 3c 2 3d 2 3e 2 3f 2 4a 2 4b 2 4c 2 4d 2 4e ...
Страница 61: ...Manuel d installation e MatriX heat 800 500 RD ST LL 60 3 0a 3 0b 3 1a 3 1b 3 1c 4 0 ...
Страница 63: ...Manuel d installation e MatriX heat 800 500 RD ST LL 62 6 0 6 1 ...
Страница 64: ...Manuel d installation e MatriX heat 800 500 RD ST LL 63 7 0 7 1 7 2 7 3 7 4 7 5 7 6 8 0 ...
Страница 71: ...Manuel d installation e MatriX heat 800 500 RD ST LL 70 12 Dessins cotés 12 1 e MatriX heat 800 500 RD LL ...
Страница 72: ...Manuel d installation e MatriX heat 800 500 RD ST LL 71 12 2 e MatriX heat 800 500 ST LL ...
Страница 73: ...Manuel d installation e MatriX heat 800 500 RD ST LL 72 12 3 Boîtier de commande ...
Страница 75: ......
Страница 76: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...