background image

Manual e-MatriX 800-RD/ST (LL) 

-------------------------------------------------------------------------------------------------------------------------------------- 

16 < 

<

 

<

 

<

 

10.1.2

 

Cleaning air filter 

 

Gently slide the air filter upwards out of its plastic holder see fig. 8.0. 

 

Gently rinse with water in the sink and dry with fabric towel before returning. 

 

Replace the filter making sure that the coarse black filter is facing the front of the fire. 

 

Place the fuel bed see Chapter 6. 

 

Place the front glass see Chapter 5.1.1 or 5.2.1. 
 

10.1.3

 

Replacing transducers 

!! Always press the mains switch of the Control box to the OFF position (see fig. 4.0) and disconnect 
the power supply. 

 

The transducers are fixed in the water sump with plastic clips. 

 

Follow the first 5 steps in Chapter 10.1.1 to gain access to the transducers. 

 

Press the clip back and lift the transducer upwards out of its holder. 

 

Place the new transducers and repeat the steps above in reverse order. 
 

10.1.4

 

Cleaning mesh filter 

 

Turn off the water supply. 

 

Close the ball valves. 

 

Unscrew the base and clean the filter inside. 

 

10.1.5

 

Replacing in-line filter 

 

Turn off the water supply. 

 

Close the ball valves. 

 

Replace the in-line filter.  
(Place it in correct alignment, there’s a “flow” direction marking on the filter). 

 
10.2

 

Resetting absorption valve (see fig. 5.0-K) 

The absorption valve is located on the right front side at the bottom of the Engine. 

 

Take out the activated absorption pill. 

 

Fix the cause of the water leakage and remove any water at the bottom of the Engine. 

 

Place the new pill and open the absorption valve by pressing down the white clamp. 

 
 

 

Содержание e-MatriX 800-RD

Страница 1: ...Manual e MatriX 800 RD ST LL ENG 40011693 1845 Manual e MatriX 800 RD ST LL ENG...

Страница 2: ...Manual e MatriX 800 RD ST LL 2 Registration plate...

Страница 3: ...Manual e MatriX 800 RD ST LL 3 1 0 1 1a 1 1b 1 2 2 0a...

Страница 4: ...Manual e MatriX 800 RD ST LL 4 2 0b 2 0c 2 1 2 2 2 3a 2 3b 2 3c...

Страница 5: ...Manual e MatriX 800 RD ST LL 5 2 3d 2 3e 2 3f 2 4a 2 4b 2 4c 2 4d 2 4e...

Страница 6: ...Manual e MatriX 800 RD ST LL 6 3 0a 3 0b 3 1a 3 1b 3 1c 4 0...

Страница 7: ...Manual e MatriX 800 RD ST LL 7 4 1 4 2 4 3 5 0...

Страница 8: ...Manual e MatriX 800 RD ST LL 8 6 0 6 1...

Страница 9: ...Manual e MatriX 800 RD ST LL 9 7 0 7 1 7 2 7 3 7 4 8 0...

Страница 10: ...he product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 these cover the essential requirements o...

Страница 11: ...out cover strip A Remove distance holder B around Build the false chimney breast or plateau against the appliance 4 3 2 e MatriX ST see fig 1 2 4 3 2 1 With cover strip A Build the false chimney breas...

Страница 12: ...pter 9 and check all connections for water leakage before placing the fuel bed and front glass 4 5 Build in structure The e MatriX needs a minimum ventilation of 50cm above and 210cm underneath the fi...

Страница 13: ...Chapter 5 1 1 or 5 2 1 Cover remove the frame to avoid scratches see fig 3 0b Turn the handles in the fuel bed see fig 3 0a Lift up the fuel bed carefully disconnect the plug and store it at a safe pl...

Страница 14: ...alves are open and turn on the water supply Switch the fire on by pressing the mains switch to the ON position and pressing the button see Chapter 8 1 and 8 2 o If the water level is high enough the f...

Страница 15: ...y and or the running hours and therefore can differ from the above mentioned 10 1 1 Cleaning water sump Always press the mains switch to the OFF position and disconnect the power supply see fig 4 1 Ne...

Страница 16: ...er 10 1 1 to gain access to the transducers Press the clip back and lift the transducer upwards out of its holder Place the new transducers and repeat the steps above in reverse order 10 1 4 Cleaning...

Страница 17: ...open See Chapter 10 2 e MatriX will not operate the LED s continuously to blink once every eight seconds Water level too high Check the electromechanical valve in the Control box e MatriX will not op...

Страница 18: ...Manual e MatriX 800 RD ST LL 18 13 Dimensional Drawings 13 1 e MatriX 800 500 RD LL...

Страница 19: ...Manual e MatriX 800 RD ST LL 19 13 2 e MatriX 800 500 ST LL...

Страница 20: ...Manual e MatriX 800 RD ST LL 20 13 3 Control box...

Страница 21: ...Manual e MatriX 800 RD ST LL 21 13 4 Remote access door...

Страница 22: ...Manual e MatriX 800 RD ST LL 22...

Страница 23: ...Manual e MatriX 800 RD ST LL 23...

Страница 24: ......

Отзывы: