background image

 

Installation and user manual

 

 

3 < 

<

 

<

 

<

 

 

The  operator  must  use  the  tools  provided. 
We recommend  using  protective  gloves when 
handling  or  using  the  appliance.  Any  glove 
provided is considered a tool. 

 

This  appliance  is  only  suitable  for  burning 
wood logs. It is not  suitable for burning other 
fuels  including  treated  wood,  woodchips, 
waste materials, carton or paper. 

 

Burn  only  p r o p e r l y   s e a s o n e d   wood  with 
a  low  moisture  content  less  than  20%. 
Burning wet unseasoned timber will only result 
in  a  build  up  of  tar  in  the  stove  and  the 
chimney and will cause staining of the glass. 

 

Do  not  burn petroleum coke  fuels, household 
waste or plastic in this appliance. 

 

Never  use  flammable  liquids  to  start  up  the 
fire.  Only  use  special  ignition  firelighters  or 
kindling wood. Avoid the use of aerosols in the 
vicinity of the stove when it is in operation. 

 

When lighting the fire for the first time, run for 
several  hours  on  the  highest  setting,  so  that 
the  paint  can  cure.  During  this  period  smoke 
and  an  unpleasant  smell  may  be  generated. 
Adequate  ventilation  must  be  provided  by 
opening  windows  and  doors,  so  that  any 
fumes  can  disperse;  we  recommend  vacating 
the room during this process. 

 

 

If  with  the  first  heating  the  maximum 
temperature  is  not  reached,  the  above-
mentioned effects may as well arise later on. 

 

The  doors  in  front  of  the  fire  must  be  closed 
when the stove is running. 

 

Ensure  that  the  ashtray  should  be  fully 
inserted,  and  in  particular  never  remove  hot 
ash from the fireplace (fire risk). Do not allow a 
build up of ash to occur in the ash pan as this 
will cause the grate to burn out prematurely. 

 

Clean  your  chimney  at  least  twice  a  year  and 
check the baffle plate monthly to ensure there 
are no blockages.  

 

Regular maintenance should be carried out by 
a suitably qualified engineer.  

 

If  work  is  being  carried  out  on  flammable  or 
explosive materials in the vicinity of the stove, 
the stove must be put out of operation.  
 

 

If  a  chimney  fire  occurs,  shut  the  air  intake, 
extinguish  the  fire  with  sand  and  contact  the 
fire department immediately. 

 

3

 

Installation requirements

 

 

3.1

 

Fluepipe and terminal requirements 

 

 

The  chimney  must  be  suited  for  the  use  of 
wood burning cassettes. 

 

Before  installation  check  and  clean  the 
chimney system. 

 

The used chimney must be fully airtight. 

 

Make  sure  that  the  chimney  is  accessible  for 
cleaning intervals. 

 

Make  sure  that  in  the  horizontal  chimney 
sections no soot particles can accumulate. 

 

The diameter of the chimney must be at least 
the same size as the flue spigot on top of the 
cassette.  

 

The minimum flue draught must be at least 12 
Pa when having a warm chimney. 

 

When  having  a  too  strong  chimney  draught  a 
damper must be used. 

 

Mount the chimney system in such a way that 
rainwater entry is prevented. 

 

The  chimney  system  cannot  rest  on  the 
cassette. 

 

3.2

 

Terminals 

 

Verify if the position of the terminal meets the 
local 

regulations 

regarding 

ventilation 

openings. 
 

3.3

 

General safety precautions 

The following fire safety requirements must be met on 
installations of the wood cassette: 

 

Installation  and  maintenance  can  only  be 
done by qualified installers. 

 

Install  the  wood  cassette  and  fluepipes  in 
front  of  non-combustibles  walls,  minimum 
distance to non-combustibles is 50mm. 

 

Distance  to  combustible  materials  such  as 
curtains, furniture, etc. 1000mm 
 

 

4

 

Preparation 

and 

installation 

instructions 

 

4.1

 

Mounting optional 3 sided trim 

 
If desired an optional 3 sided trim can be mounted, see 
par. 7.5 for more detailed information. 
 

4.2

 

Self-closing door 

The  cassette  has  a  self-closing  door  mechanism  and  if 
needed  this  mechanism  can  be  removed  easily.  See 
par.7.6 for more details.  
 

4.3

 

Optional convection air openings 

Содержание Dimplex 510 I

Страница 1: ...Faber Dimplex cassettes 510 I 650 I 700 I ...

Страница 2: ...Installation and user manual 1 1 1 1 2 1 3 1 4 ...

Страница 3: ...or domestic heating use only in accordance with these operating instructions Do not make any unauthorised changes to the appliance This appliance must be installed by a suitably qualified competent person in accordance with BS8308 Code of practice for installing domestic heating and cooking apliances burning solid mineral fuel Installation must comply with all Building Regulations including those ...

Страница 4: ... should be carried out by a suitably qualified engineer If work is being carried out on flammable or explosive materials in the vicinity of the stove the stove must be put out of operation If a chimney fire occurs shut the air intake extinguish the fire with sand and contact the fire department immediately 3 Installation requirements 3 1 Fluepipe and terminal requirements The chimney must be suite...

Страница 5: ...y that a flammable and hazardous situation is avoided at all time Take adequate measures to prevent high temperatures in the chimneybreast and surrounding constructions This also applies to materials or objects behind walls etc Remove all packed parts out of the combustion chamber Check if any loose parts need to be removed from the ashtray Check the physical state and correct position of the heat...

Страница 6: ...sed the door if the fire does not light immediately then keep the door a bit open for some time Let the fire burn for a while so that the chimney heats up properly 7 2 Heating Let the fire burn on smaller logs for some time so that a smoldering fuel bed will be formed Refill de cassette with bigger logs After 15 20 minutes the output can be adjusted by the combustion control handle fig 1 1 slide i...

Страница 7: ...ood Flue gas temperature deg C 264 252 237 Flue gas volume g s 2 7 4 2 6 9 Min flue draft Pa 12 12 12 Nom Output kW 4 5 5 6 5 Efficiency 80 83 81 Wood length cm 25 25 25 Dust at 13 O2 mg Nm3 30 30 30 Consumption kg h 1 15 1 6 1 95 Flue size mm 150 150 180 Weight kg 65 74 87 Dimplex 510 I ...

Страница 8: ...Dimplex 700 I Dimplex 650 I ...

Страница 9: ...7 5 Changing the trim Remove bolt Lift and move forwards ...

Страница 10: ...7 6 Removal of self closing mechanism Remove bolts and change replace trim Remove bolt ...

Страница 11: ...Lift up and move forwards click and remove spring ...

Отзывы: